Mounted Filters With Bypass - Beko DRYPOINT XCe 80 Installation And Operating Manual

Heatless regenerated dryer
Table of Contents

Advertisement

Optimal Installation Diagram
1
Air Compressor
2
After Cooler
3
CLEARPOINT® Inline Water Separator
4
CLEARPOINT® 5.0 Micron (Grade G) Filtration
5
Receiver Tank
6
CLEARPOINT® 1.0 Micron (Grade F) Filtration
7
DRYPOINT® XCe Desiccant Dryer with CLEARPOINT® Pre and Post-filtration
8
Dry Air Outlet
9
Condensate Drainage Points for BEKOMAT®
Optimal installation is with moderately-sized receivers at the inlet and outlet side of the dryer. This allows for the
additional free cooling and moisture collection and more consistent dryer inlet flow provided by an upstream receiver,
while providing the most reliable shop air supply due to the downstream receiver.
Under no circumstances should the peak demand air flow exceed the maximum rated air flow of the dryer.
We recommend the dryer be installed with a 0.01 micron CLEARPOINT® coalescing pre-filter at the
inlet and a 1 micron CLEARPOINT® particulate post-filter at the outlet. It is recommended to install
both 5 micron and 1 micron filters upstream of the dryer in order to maintain the operational lifespan
of the inlet filter.
2.4

Mounted Filters with Bypass

Mounted Filters with Bypass is an optional setup for DRYPOINT XC. The three
valve system bypass allows for the flow of air to be uninterupted while servicing
or completing preventative maintinance such as:
+ Exchange pre- and post- filters
+ Services exhaust silencers
+ Change desiccant
DRYPOINT® XC Series Heatless Regenerated Dryers: IOM10003
(Rev.I)
6