TROUBLESHOOTING GUIDE

The troubleshooting and the eventual checks must be performed by qualified personnel only.
The technician that services the machine must wear hearing and eye protection while servicing the dryer.
Each employee must select a proper personal protection device (PPD) hearing protector such as earmuffs,
ear canal caps or earplugs in order to prevent permanent hearing damage or loss.
SYSTEM TROUBLE
 T he service LED
 Service Reminder
on
the controller is
flashing amber
 Service Due
or red.
 Dryer stopped
 No power
 Valve problem
 No pilot control air
 Solenoid valves
 Controller
 Compressor off
 All the inlet air
 Faulty inlet valve
is discharged
 Faulty signal
through the
silencers
 Faulty Outlet valve
 Pneumatic
 Liquid comes out
 High dew point
of the silencers
 Overloaded
 No power
 Flow control valve
 No pilot control air
 Exhaust Silencers
 Repressurization  Purge Exhaust Valve
 Purge line
 Purge Valve
 Inlet Valve
DRYPOINT® XC Series Heatless Regenerated Dryers: IOM10003
POSSIBLE CAUSE
 I f the service LED indicator light is flashing amber this is
 I f the service LED indicator light is flashing red then the dryer
 Check power and electric
 Check the operation of inlet and purge exhaust valves
 Ensure Control pilot air is delivering at 80 psi
 Ensure DIN connectors are properly attached to solenoid valves
 See controller troubleshooting
 Check if compressor Sync is commanding dryer off
 The inlet valves are blocked – open and clean
 T he controller continuously supplies solenoid valve PVA and/or
 O utlet Check valve(s) stuck open – serviceable only by qualified
 Ensure tube routing matches diagram
 Ensure operation sequence and purge setting
 Check capacity versus operating conditions
 Check purge exhaust valve for normal operation
 Ensure that the purge exhaust valve actuators is not closed
 Ensure pilot air reading is 80 psi
 Replace silencer filter elements if clogged
 See purge Exhaust Valve troubleshooting
 Purge setting or clog, full open purge valve to clean out and
then set according to table xx
 See Purge valve troubleshooting
 See Inlet Valve Failure troubleshooting
SUGGESTED ACTION
an indication that the dryer is approaching the annual
maintenance interval, and schedule maintenance should be
performed within the next 5-days. – 360 hours
is overdue for scheduled maintenance by approximately one
month, and should be serviced immediately to ensure trouble
free operation. – 400 hours
PVB – check the electric wiring and if necessary replace
technician