Fiber Unit
Long distance/Dust resistance (High-power), Detection through gaps
(Narrow vision field)
Sensing
Type
method
High-power
(integrated unit)
Through-
High-power
beam
(with lens unit)
models
Narrow vision
field (aperture
angle: 4°)
Reflective
High-power
models
✽1. The fiber length is 10 m on each side, so the sensing distance is given as 20,000 mm.
✽2. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
Fiber Unit
Minute object detection (Small-spot model)
Sensing
Spot diameter
method
(mm)
φ0.1 to 0.6
(Variable)
φ0.1
φ0.2
Reflective
φ0.5
models
φ6
φ4
Parallel light
φ3
For information on Fiber Units, refer to the Fiber Sensors Best Selection Catalog (Cat. No. E353).
Sensing
direction/
Model
Lens type
Top view
E32-T17L 10M
Side view
E32-T14 2M
High-power
E32-T11N 2M + E39-F1
Ultrahigh-power E32-T11N 2M + E39-F16
High-power
E32-T11R 2M + E39-F1
Ultrahigh-power E32-T11R 2M + E39-F16
Side view
E32-T11R 2M + E39-F2
High-power
E32-TC200 2M + E39-F1
Ultrahigh-power E32-TC200 2M + E39-F16
Side view
E32-TC200 2M + E39-F2
High-power
E32-T11 2M + E39-F1
Ultrahigh-power E32-T11 2M + E39-F16
Side view
E32-T11 2M + E39-F2
High-power
E32-T11U 2M + E39-F1
Ultrahigh-power E32-T11U 2M + E39-F16
Side view
E32-T11U 2M + E39-F2
High-power
E32-T11NU 2M + E39-F1
Ultrahigh-power E32-T11NU 2M + E39-F16
High-power
E32-T81R-S 2M + E39-F1
Ultrahigh-power E32-T81R-S 2M + E39-F16
Side view
E32-T81R-S 2M + E39-F2
High-power
E32-T61-S 2M + E39-F1
Ultrahigh-power E32-T61-S 2M + E39-F16
Side view
E32-T61-S 2M + E39-F2
Top view
E32-T22S 2M
Side view
E32-T24S 2M
Top view
E32-D16 2M
Focal length
Model
(mm)
6 to 15
E32-C42 1M + E39-F3A
5
E32-C42S 1M
7
E32-C41 1M + E39-F3A-5
17
E32-C41 1M + E39-F3B
7
E32-C31 2M + E39-F3A-5
17
E32-C31 2M + E39-F3B
50
E32-L15 2M
0 to 20
E32-C31 2M + E39-F3C
E32-C11N 2M + E39-F18
50
E32-CC200 2M + E39-F18
Amplifier Unit
Sensing distance (Unit: mm)
E3X-SD@
E3X-NA@
Standard
models
20,000 ✽1
3,600
3,700
4,000 ✽2
4,000 ✽2
4,000 ✽2
440
4,000 ✽2
4,000 ✽2
700
4,000 ✽2
4,000 ✽2
720
3,600
4,000 ✽2
660
1,800
4,000 ✽2
1,800
4,000 ✽2
280
4,000 ✽2
4,000 ✽2
780
2,000
1,400
800
Amplifier Unit
Sensing distance (Unit: mm)
E3X-SD@
E3X-NA@
Standard
models
Spot diameter of 0.1 to 0.6 mm at 6 to 15 mm
Spot diameter of 0.1 mm at 5 mm
Spot diameter of 0.1 mm at 7 mm
Spot diameter of 0.2 mm at 17 mm
Spot diameter of 0.5 mm at 7 mm
Spot diameter of 0.5 mm at 17 mm
Spot diameter of 6 mm at 50 mm
Spot diameter of 4 mm max. at 0 to 20 mm
Spot diameter of 3 mm at 50 mm
Spot diameter of 3 mm at 50 mm
E3X-SD/-NA
E3X-NA@F
E3X-NA@V
High-speed
Water-resistance
detection models
models
8,400
14,000
1,080
1,800
1,110
2,100
2,000
3,600
1,260
2,100
2,000
3,600
130
220
1,800
3,000
4,000 ✽2
3,000
210
350
1,200
2,000
4,000 ✽2
2,600
200
360
1,080
2,000
4,000 ✽2
2,600
198
330
700
1,500
1,500
2,700
630
1,100
1,300
2,300
84
140
1,800
3,000
2,340
3,900
260
390
600
1,000
420
700
140
40 to 400
E3X-NA@F
E3X-NA@V
High-speed
Water-resistance
detection models
models
7