GRAUPNER ULTRA DUO PLUS 30 Operating Manual page 20

Table of Contents

Advertisement

Available languages

Available languages

NiCd / NiMH charge termination delay
At the start of the charge process the unit initiates a delay time
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
c h a r g e
c u t - o f f
which suppresses automatic charge termination during this
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
d e l a y
t i m e
= 3 m i n
(delay) period. This means: during this delay period the charge
voltage is not monitored, and the battery is charged for at
+
-
least the set length of time! The charge termination delay is
INC
DEC
only effective n the NiCd and NiMH charge programs.
Warning: if you connect an already fully charged battery with the purpose of topping it up, it will be
charged for at least the delay time you have selected, and could then get very hot.
Caution - explosion hazard!
NiCd / NiMH safety timer
When you start a charge process, the integral safety timer au-
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
s a f e t y
t i m e r
tomatically starts running at the same time. The safety timer is
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
1 2 0
m i n .
designed to prevent catastrophic overcharging of the battery
on charge if the pack proves to be faulty, or if the "battery full"
+
-
detection circuit malfunctions. The value you set for the safety
INC
DEC
timer must be generous enough to allow a full charge of the
battery. As a practical guide we recommend a time which is about 30% longer than the expected charge
period; naturally, this varies according to the charge current you have set. Example: 1.8 Ah battery,
charge current 3.6 A -> charge time = 1.8 Ah / 3.6 A - 0.5 hours = 30 min +30% = safety timer = 40 min.
Maximum Automatic current
In this program the charger detects the types of battery
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
N i C d
m a x .
c u r r .
connected and adjusts the charge current accordingly, to
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
a u t o m a t i c :
2 . 5 A
avoid overcharging the pack.
The maximum charge current can be set using the INC /
+
-
DEC buttons before you connect the battery to be
INC
DEC
charged.
The charge process is terminated according to the values
set by the user for „NiCd Delta-Peak Termination Voltage",
„Charge Termination Delay" and „Safety Timer".
Initial power-on current (NiCd, NiMH, Pb)
You can select the charge / discharge current which is to be
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
N i C d
s t a r t
c u r r .
set automatically when the charger is connected to the car
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
2 . 5 A
battery. In this program segment the value can be set separa-
tely for each of the charge programs (NiCd, NiMH, LiIo, Pb
+
-
and charging output „Akku 2").
INC
DEC
N i C d
s t a r t
c u r r .
3 . 7 A
N i M H
s t a r t
c u r r .
3 . 7 A
L i t h i u m - S t a r t
1 . 2 A
P b
s t a r t
c u r r .
1 . 2 A
B a t t . 2
s t a r t c u r r
2 5 0 m A
38
This is particularly useful if you always
use the same charge current, as it avoids
the necessity to select the value sepa-
ENTER
rately each time you use the charger.
In any case we recommend that you set
a "starting point" value of 2.5 A, as this
avoids the need to run through the enti-
re range every time you start using the
charger.
Car battery low voltage cut-off
If the charger is connected to a car battery which is not
l o w
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
v o l t a g e
required to start a car engine at the end of the session, then
c u t
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
o f f . =
1 1 . 8 V
it is safe to discharge it to a lower level.
The charger allows you to set an alternative value of 10.5 V,
which enables you to exploit the maximum capacity of the car
INC
DEC
battery without deep-discharging it excessively.
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
l o w
v o l t a g e
The unit does not store the alternative setting, so you must
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
c u t
o f f . =
1 0 . 5 V
reset it (if required) every time you start using the charger.
Button click / buzzer settings
The purpose of this sub-menu is to adjust the settings for the audible sounder.
Button click:
Every time you press a button you will hear a "click" sound to confirm your action. This
sound can be switched on (EIN) or off (AUS).
Buzzer:
When the screen displays a warning, "completed" or an error message etc., the inte-
gral buzzer sounds at the same time to alert you. In this program point you can select
buzzer off (AUS), or the length (10 sec. or no time limt) of the audible warning.
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
b u t t o n
c l i c k
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
O N
INC
DEC
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
b u t t o n
c l i c k
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
O F F
Erase user settings
This menu provides the means to reset all the user settings
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C l e a r
to their standard default values:
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
U s e r
S e t t i n g s
Initial power-on program
+
NiCd Delta Peak
INC
DEC
NiMH Delta Peak
Charge termination delay
Safety timer
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C l e a r
Initial power-on current
Car battery low voltage
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
* * * e r a s e d * * *
Button click
Buzzer setting
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
B u z z e r
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
O F F
INC
ENTER
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
B u z z e r
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
o f f
a f t e r
1 0 s e c .
INC
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
B u z z e r
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
n o
t i m e
l i m i t
INC
:
NiCd Automatik
:
20 mV / cell
:
15 mV / cell
:
3 min
:
120 min
:
2.5 A (NiCd, NiMH, PB)
:
11.8 V
:
ON
:
10 sec.
DEC
DEC
DEC
39

Advertisement

Table of Contents
loading

This manual is also suitable for:

6416

Table of Contents