7. Locate the electrical box, from the front of the machine, and
remove the screw on the right side holding it in place. Grab
the left tab of the box and pull forward.
NOTE: The connectors in the back will tend to give
some resistance when pulling on the box.
8. You will now be able to access the GBIC. To remove slide
module to the right. When box stops push up and pull for-
ward.
9. Remove plugs from GIBC by pulling connectors from rear of unit. Plugs may be difficult to remove. (NEVER
PULL ON WIRES AS THEY MAY COME LOOSE FROM CONNECTOR BODY). If connector body is damaged
replace with the proper connector body supplied in the kit. Refer to the drawing in the beginning of the installation
sheet for proper connector and wire locations.
10. Reverse the above procedure to reassemble machine.
CAUTION: When reinstalling the new GIBC be sure not to pinch wires between any parts of the
frame. With the side panel off inspect that the wires are free and not trapped where they could
become pinched and short out to the cabinet frame.
NOTE: It is also recommended that before reattaching the panels to the machine reinstall the control
and verify machine functions properly. If any part of the dispenser does not function properly
such as pumps, disconnect power and reinstall GIB control. Be sure connector is seated prop-
erly in connectors.