Chapter 2: Installation Instructions - Frymaster FPRE314 Installation & Operation Manual

Table of Contents

Advertisement

CHAPTER 2: INSTALLATION INSTRUCTIONS

2.1
General
Proper installation is essential for the safe, efficient, trouble-free operation of this appliance.
Qualified, licensed, and/or authorized installation or service personnel, as defined in Section
1.6 of this manual, should perform all installation and service on Frymaster equipment.
Failure to use qualified, licensed, and/or authorized installation or service personnel (as
defined in Section 1.6 of this manual) to install or otherwise service this equipment will void
the Frymaster warranty and may result in damage to the equipment or injury to personnel.
Where conflicts exist between instructions and information in this manual and local or
national codes or regulations, installation and operation shall comply with the codes or
regulations in force in the country in which the equipment is installed.
Service may be obtained by contacting your local Factory Authorized Servicer.
All fryers shipped without factory supplied cords and plug assemblies must be
hardwired using flexible conduit to the terminal block located on the rear of the fryer.
These fryers should be wired to NEC specifications. Hardwired units must include
installation of restraint devices.
Adequate means must be provided to limit the movement of this appliance without
depending on or transmitting stress to the electrical conduit.
provided with the fryer. If the restraint kit is missing contact your local Frymaster
Factory Authorized Servicer (FAS) for part number 826-0900.
If this equipment is wired directly into the electrical power supply, a means for
disconnection from the supply having a contact separation of at least 3-mm in all
poles must be incorporated in the fixed wiring.
This equipment must be positioned so that the plug is accessible unless other
means for disconnection from the power supply (e.g., a circuit breaker) is provided.
If this appliance is permanently connected to fixed wiring, it must be connected by
means of copper wires having a temperature rating of not less than 167°F (75°C).
If the electrical power supply cord is damaged, it must be replaced by a Frymaster
Dean Factory Authorized Servicer technician or a similarly qualified person in order
to avoid a hazard.
4
RE SERIES E
NOTICE
NOTICE
NOTICE
NOTICE
NOTICE
ELECTRIC FRYERS
DANGER
2-1
A restraint kit is

Advertisement

Table of Contents
loading

Table of Contents