Figure 1. Electrical Wiring Installation Instructions - Remcor SID650A/80 Operator's Manual

Spiral icemaker dispenser operator's manual sid650a/80, sid650a/80-b, sid650a/80-bc, sid650w/80, sid650w/80-b, sid650w/80-bc
Hide thumbs Also See for SID650A/80:
Table of Contents

Advertisement

IMPORTANT: To ensure proper ice maker operation and also to reduce the frequency of water-related
service problems, a water filter should be installed. Remcor recommends the use of IMI Cornelius filter,
model number 81COR01PS.
For specific recommendations on these filter systems for your local conditions, consult with a distributor in your
area or contact the filter manufacturer.
Connect two (2) 3/4 IPS (or equal) drain lines to the 3/4 threaded drain connections at the lower rear of the
unit. These lines must pitch downward to an open drain and must contain no traps or improper drainage
will result.
NOTE: In areas where consistently warm water temperatures are encountered, the use of a Remcor Pre-
Cooler in the water line is recommended to maximize the ice production of this unit. Contact Remcor
for more information on this product.
3. Electrical
A 4 x 2 junction box is located at the rear of the unit for the supply hook-up. Connect the ice maker to its
own individual circuit per the national electric code and local code. See SPECIFICATIONS for ampacity
and fuse size.
IMPORTANT: The wire size must be adequate for the ampacity rating, and the supply voltage must be
within a range of ± 10% for proper ice maker operation.
NOTE: The units require a 2 wire system plus earth ground for proper operations.
SUPPLY CONDUIT

FIGURE 1. ELECTRICAL WIRING INSTALLATION INSTRUCTIONS

BROWN (HOT)
220V
1 PHASE
60 HERTZ
REAR VIEW -- BOTTOM SECTION SERVICE PANEL REMOVED
BLUE (NEUTRAL)
GREEN (GROUND)
3
91704