Technical data
Table 8- 2
Process connections
Version
EN 1092-1, raised face
(EN 1092-1, DIN 2501 & BS
4504 have the same mating
dimensions)
ANSI B16.5 (~BS 1560),
raised face
AWWA C-207, flat face
AS 2129, raised face
AS 4087, raised face
JIS B 2220:2004
Other flanges and pressure
ratings
48
MAG 3100 P
DN 15 ... 50
(½" ... 2"):
PN 40 (580 psi)
DN 65 ... 300
(2½" ... 12"):
PN 16 (232 psi)
DN 200 ... 300
(8" ... 12"):
PN 10 (145 psi)
½" ... 12": Class 150
(20 bar (290 psi))
-
-
-
-
-
MAG 3100
DN 65 ... 2000
(2½" ... 78"):
PN 6 (87 psi)
DN 200 ... 2000
(8" ... 78"):
PN 10 (145 psi)
DN 65 ... 2000
(2½" ... 78"):
PN 16 (232 psi)
DN 200 ... 600
(8" ... 24"):
PN 25 (362 psi)
DN 15 ... 600
(½" ... 24"):
PN 40 (580 psi)
DN 50 ... 300
(2" ... 12"):
PN 63 (913 psi)
DN 25 ... 300
(1" ... 12"): PN 100
(1450 psi)
½" ... 24": Class 150
(20 bar (290 psi))
½" ... 24": Class 300
(50 bar (725 psi))
28" ... 78": Class D (10 bar)
½" ... 48": Table E
PN 16 (DN 50 ... 1200,
16 bar (232 psi))
PN 21 (DN 50 ... 600,
21 bar (304 psi))
PN 35 (DN 50 ... 600,
35 bar (508 psi))
K10 (½" ... 24")
K20 (½" ... 24")
On request
Operating Instructions, 09/2012, A5E03005599-02
MAG 3100 HT
DN 15 ... 300
(½" ... 12"):
PN 40 (580 psi)
DN 65 ... 300
(2½" ... 12"):
PN 16 (232 psi)
DN 200 ... 300
(8" ... 12"):
PN 10 (145 psi)
DN 200 ... 300
(8" ... 12"):
PN 25 (362 psi)
½" ... 12": Class 150
(20 bar (290 psi))
½" ... 12": Class 300
(50 bar (725 psi))
-
½" ... 12": Table E
-
-
On request