Surface Burners; Assembling The Surface Burners; Checking Ignition Of The Surface Burners - LG LTGL6937D.BBDELGA Owner's Manual

Hide thumbs Also See for LTGL6937D.BBDELGA:
Table of Contents

Advertisement

Available languages

Available languages

18 INSTALLATION
Fuel Gas Code, ANSI Z223.1/NFPA 54 or, in
Canada, the Natural Gas and Propane
Installation Code, CSA B149.1.
NOTE
• Ground Fault Circuit Interrupters
- GFCI's are not required or recommended for
gas range receptacles.
- Ground Fault Circuit Interrupters (GFCI's) are
devices that sense leakage of current in a
circuit and automatically switch off power
when a threshold leakage level is detected.
These devices must be manually reset by the
consumer. The National Electrical Code
requires the use of GFCI's in kitchen
receptacles installed to serve countertop
surfaces.
- Performance of the range will not be affected
if operated on a GFCI-protected circuit but the
occasional resetting of the circuit can become
an annoyance.

Surface Burners

Assembling the Surface Burners

CAUTION
• Do not operate the burners without all parts in
place.
1
Place the burner caps and heads on the
cooktop.
• There is one small, one medium, one large,
one oval (center), and one extra large
burner head and cap.
2
Make sure that the caps and heads are placed
in the correct locations.
3
Make sure that the hole in the burner head is
positioned over the electrode.
Oval (center) burner head/cap assembly
a
Medium burner head and cap
b
Small burner head and cap
c
Large burner head and cap
d
Front of range
e
Dual burner head and cap
f
Hole
g
Electrode
h
Checking Ignition of the Surface
Burners
Electric Ignition
Select a surface burner knob and simultaneously
push in and turn to the Lite position. You will hear
a clicking sound indicating proper operation of the
spark module.
Once the air has been purged from the supply
lines the burner should ignite within 4 seconds.
After the burner ignites, rotate the knob out of the
Lite position. Try each burner in succession until
all burners have been checked.
Quality of Flames
The combustion quality of the burner flames
needs to be confirmed visually.

Advertisement