Adjusting Flow Rates - Cornelius Impulse Non-Carbonated Post-Mix Beverage Dispenser Installation And Operation Manual

Cornelius non-carbonated post-mix beverage dispenser installation & operation manual
Table of Contents

Advertisement

Adjusting Flow Rates

Flow rates of the water and concentrate are adjusted based on the desired ratio. For example: if the
desired ratio is 5:1, then the flow rate of the water is 5 times that of the concentrate.
If the desired finished drink flow rate is 3.0 ounces per second, then the water flow rate is 2.5 oz./sec.
and the concentrate flow rate is 0.5 oz./sec. (The water at 2.5 oz./sec. is five times the 0.5 oz./sec. con-
centrate flow rate.)
Finished Drink oz./sec.
© 2003, IMI Cornelius Inc.
Non-Carbonated Impulse Installation & Operations Manual
Flow Rates oz./sec. Based on 5:1 Ratio
Water oz./sec.
1.5
2.0
2.5
3.0
3.5
4.0
4.5
- 5 -
Concentrate oz./
sec.
1.25
.25
1.67
.33
2.08
.42
2.5
.50
2.92
.58
3.33
.67
3.75
.75