Non-Carbonated Impulse Installation & Operations Manual
Publication Number: 859000159INS
• No power source. Blown fuse
or. tripped circuit breaker
• Agitator motor propeller
obstructed.
• Low voltage at compressor ter-
minals.
• Loose, disconnected, or bro-
ken wiring.
• Inoperative agitator motor.
- 14 -
• Replace fuse or reset circuit
breaker (note: Fuse or circuit
breaker are not part of unit).
• Remove obstruction.
• Voltage must be at least 103
volts at the compressor termi-
nals when compressor is trying
to start.
• Tighten connections or replace
broken wiring.
• Replace agitator motor as
instructed.
© 2003, IMI Cornelius Inc.