EXTERNAL CONTROL DEVICE SETUP
RS-232C Configurations
7-Wire Configurations
(Standard RS-232C cable)
PC
2
RXD
TXD
3
GND
5
DTR
4
DSR
6
RTS
7
CTS
8
D-Sub 9
3-Wire Configurations
(Not standard)
PC
RXD
2
TXD
3
GND
5
DTR
4
DSR
6
RTS
7
CTS
8
D-Sub 9
Set ID
Set ID number. "Real Data Mapping".
1
TV
2
3
TXD
3
2
RXD
GND
5
4
DSR
6
DTR
4
5
CTS
8
RTS
7
D-Sub 9
TV
3
TXD
2
RXD
5
GND
6
DTR
4
DSR
7
RTS
CTS
8
D-Sub 9
Press SETTINGS or HOME to access the
main menus.
Press the Navigation buttons to scroll to
OPTION and press OK.
Press the Navigation buttons to scroll to Set
ID and press OK.
Scroll left or right to select a set ID number
and select Close. The adjustment range is
1-99.
When you are finished, press EXIT.