Installation Instructions
A device must be provided in the electrical installation which allows the appli-
ance to be disconnected from the mains at all poles with a contact opening
width of at least 3 mm
Suitable isolation devices include line protecting cut-outs, fuses (screw type fus-
es are to be removed from the holder), earth leakage trips and contactors.
Sticking on the seal
• Clean the worktop in the area of the cut-out section.
• Stick the one-sided self-adhesive sealing tape supplied all the way round the
lower edge of the cooking surface along the outer edge of the glass ceramic
panel. Do not stretch it. The cut ends should lie in the middle of one side.
When you have cut it to length (add a few mm), press the two ends flush up
against one another.