Download Print this page

Bosch 06012271K1 Original Instructions Manual page 8

Advertisement

8 | English
You can swivel the auxiliary handle (9) to any angle for a safe
work posture that minimises fatigue.
Turn the lower gripping end of the auxiliary handle (9) anti-
clockwise and set the depth stop (10).
Pull the depth stop (10) far enough out that the distance
between the drill bit tip and the edge of the depth stop (10)
corresponds to the required drilling depth X.
Then, turn the lower gripping end of the auxiliary handle (9)
clockwise to retighten it.
The fluting on the depth stop (10) must face upwards.
Changing the Tool
Keyless Chuck (see figure B)
Hold the rear sleeve (3) of the keyless chuck (1) firmly and
turn the front sleeve (2) in the rotational direction ➊ until
the tool can be inserted. Insert the tool.
Hold the rear sleeve (3) of the keyless chuck (1) and firmly
tighten the front sleeve (2) by hand in the rotational direc-
tion ➋ until it stops clicking. This will automatically lock the
drill chuck.
The lock will disengage again if you turn the front sleeve (2)
in the opposite direction to remove the tool.
Keyed chuck (see figure C)
Wear protective gloves when changing tools. The drill
u
chuck may heat up significantly when it is used for long
periods.
Open the keyed chuck (13) by turning it until the tool can be
inserted. Insert the tool.
Insert the drill chuck key (12) into the corresponding holes
of the keyed chuck (13) and clamp the tool evenly.
Screwdriving Tools (see figure D)
You should always use a universal bit holder (14) when using
screwdriver bits (15). Only use screwdriver bits that fit the
screw head.
For screwdriving, make sure the "drilling/impact drilling" se-
lector switch (4) is always set to the "drilling" symbol.
Changing the Drill Chuck
Pull the plug out of the socket before carrying out any
u
work on the power tool.
Removing the Drill Chuck (see figure E)
To remove the keyless chuck (1), clamp a hex key (16) in
the keyless chuck (1) and position an open-ended spanner
(17) (width across flats: 14) against the spanner flat of the
drive spindle.
Place the power tool on a firm surface, e.g. a work bench.
Hold the open-ended spanner (17) in place and loosen the
keyless chuck (1) by turning the hex key (16) in the rota-
tional direction ➊. A tightly seated keyless chuck can be
loosened with a light blow on the long shaft of the hex key
(16).
Remove the hex key from the keyless chuck and completely
unscrew the keyless chuck from the power tool.
1 609 92A 7XC | (15.08.2022)
The keyed chuck (13) can be removed in the same way as
described for the keyless chuck.
Fitting the Drill Chuck (see figure F)
The keyless chuck/keyed chuck with securing ring is moun-
ted in reverse order.
The drill chuck must be tightened using a tight-
ening torque of approx. 33–39 Nm.
Dust/Chip Extraction
Dust from materials such as lead-containing coatings, some
wood types, minerals and metal can be harmful to one's
health. Touching or breathing-in the dust can cause allergic
reactions and/or lead to respiratory infections of the user or
bystanders.
Certain dust, such as oak or beech dust, is considered carci-
nogenic, especially in connection with wood-treatment ad-
ditives (chromate, wood preservative). Materials containing
asbestos may only be worked by specialists.
– Provide for good ventilation of the working place.
– It is recommended to wear a P2 filter-class respirator.
Observe the relevant regulations in your country for the ma-
terials to be worked.
Avoid dust accumulation at the workplace. Dust can
u
easily ignite.
Operation
Starting Operation
Pay attention to the mains voltage. The voltage of the
u
power source must match the voltage specified on the
rating plate of the power tool. Power tools marked
with 230 V can also be operated with 220 V.
Products that are only sold in AUS and NZ: Use a resid-
u
ual current device (RCD) with a nominal residual current
of 30 mA or less.
Setting the Rotational Direction (see figure G–H)
(GSB 13 RE/GSB 16 RE)
Only operate the rotational direction switch (5) when
u
the power tool is not in use.
The rotational direction switch (5) is used to change the ro-
tational direction of the power tool. However, this is not pos-
sible while the on/off switch (7) is being pressed.
Clockwise rotation: To drill and drive in screws, slide the
rotational direction switch (5) upwards on the left-hand side
and downwards on the right-hand side at the same time.
Anti-clockwise rotation: To loosen and unscrew screws and
nuts, slide the rotational direction switch (5) downwards on
the left-hand side and upwards on the right-hand side at the
same time.
Setting the Operating Mode
Drilling and screwdriving
Set the selector switch (4) to the "drilling"
symbol.
Bosch Power Tools

Advertisement

loading