SERVICE DIAGNOSIS
SYMPTOM
Low ice production
No ice falling in bin, unit frozen up
Ice maker stuck in harvest cycle
Ice is mal-formed
Water overflows from reservoir into
bin.
POSSIBLE CAUSE
4. High head pressure, a result of a
dirty condenser
5. Hot gas valve leaks thru
6. High discharge pressure
1. Cube size control will not close
2. Timer motor open
3. Plug in relay contacts open
4. Not enough time during the
harvest cycle to drop all ice
5. Cube size wrong
6. Hot gas valve restricted.
7. Not enough water to help harvest.
8. Head pressure too low
1. Relay coil open
2. Timer stuck in harvest cycle
3. Timer microswitch N.O. contacts
will not close.
1. Shortage of water
2. Evaporator water passages
restricted.
3. Cube size set wrong
1. Restricted sump drain
2. Inlet water valve lets in too much
water
September, 1993
Page 18
PROBABLE CORRECTION
4. Clean water circuit of condenser
5. Replace hot gas valve
6. If possible, reduce condenser
water inlet temperature.
1. Check temp. of suction line, cube
size control will not close if temp.
too high. If temp. low enough,
replace cube size control
2. Replace timer
3. Replace relay
4. Adjust timer for more harvest time
5. Adjust cube size
6. Replace hot gas valve.
7. Check for restriction of water
supply.
8. Check water reg./pressure
control valve. Check for low
refrigerant charge.
1. Replace relay
2. Check for power to timer motor, if
power replace timer, if no power to
timer motor, replace relay.
3. Replace timer.
1. Check for restriction of water
supply. Check for leak.
2. Clean ice maker.
3. Adjust cube size control
1. Repair drain
2. Replace valve

Advertisement