Removal And Replacement - Scotsman CME256 Product Manual

Autoiq cubers
Hide thumbs Also See for CME256:
Table of Contents

Advertisement

CME256, 506, 656, 806: AutoIQ™ Cubers

Removal and Replacement

Drain Tubing
1. Remove the front panel.
2. Push and release the Off button.
3. Remove bin baffle.
4. Remove 1 plastic bolt and the reservoir cover.
5. Unplug water pump, disconnect ground wire.
6. Unplug water level sensor.
7. Lift pump up slightly and pull discharge hose
from pump.
8. Remove pump and water level sensor from ice
machine.
9. Pull up and forward to remove standpipe.
10. Disconnect back of cabinet drain system.
11. Remove nut on inside of reservoir (where
standpipe was).
12. From inside the bin, pull drain tube out of the
reservoir and down. Remove from machine.
13. Reverse to reassemble.
Note: The distance between the top edge of the
standpipe and the top edge of the reservoir must
be 2
5
".
8
If needed, adjust the distance by rotating the top
end of the standpipe (it is threaded).
Observe machine for proper cube size after
replacement/adjustment of the standpipe.
Standpipe
January 2002
Page 32
Water Pump
1. Disconnect the electrical power.
2. Remove the front panel.
3. Unplug water pump from its electrical
connection.
4. Remove 1 plastic bolt and the reservoir cover.
5. Lift water pump up and disconnect outlet tube.
Pump Bracket
6. Pull float ball from float stem (it is a snap fit).
Pull stem out.
7. Locate water level sensor mounting tabs,
compress together to release sensor from bracket.
8. Remove water pump brackets from pump.
9. Reverse to replace.
10. Replace front panel.
11. Re-connect electrical power.
Water Level Sensor

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cme506Cme656Cme806

Table of Contents