CME256, 506, 656, 806: AutoIQ™ Cubers
Operational Characteristics: CME806
Cycle Times (minutes)
Air Cooled
Freeze
Harvest
Water Cooled
Freeze
Harvest
System Pressures
Air Cooled
Suction: End of Freeze
Suction: Peak in Harvest
Discharge: 5 minutes into Freeze
Discharge: Minimum in Harvest
Water Cooled
Suction: End of Freeze
Suction: Peak in Harvest
Discharge:
Discharge: Minimum in Harvest
A - E Series Refrigerant Charge, R-404A
•
Air cooled: 33 ounces
•
Water cooled: 24 ounces
F Series Refrigerant Charge, R-404A
•
Air cooled: 33 ounces
•
Water cooled: 26 ounces
Typical Compressor Amps
•
Freeze: single phase = 13
•
Harvest: single phase = 14
Typical Harvest Ice Weight
•
6.5 - 7 lb.
Water Cooled:
•
Discharge Pressure: 240 - 245 PSIG
•
Hi Pressure Cuts Out at: 450 PSIG
Fan Control Switch - for units so equipped:
•
Cut In: 240 PSIG + - 20 PSIG
•
Cut Out: 190 PSIG + - 10 PSIG
o
o
70
F. indoor air, 50
F. water
9 - 11
1:45
o
o
70
F. indoor air, 50
F. water
10 - 12
1:45
o
o
70
F. indoor air, 50
F. water
20 - 21
89 - 91
210 - 220
155
o
o
70
F. indoor air, 50
F. water
24 - 26
85 - 95
240 PSIG
155
June 2002
Page 30
o
o
90
F. indoor air, 70
F. water
12 - 14
1:15
o
o
90
F. indoor air, 70
F. water
12 - 13
1:15
o
o
90
F. indoor air, 70
F. water
25 - 27
115 - 125
280 - 290
205
o
o
90
F. indoor air, 70
F. water
24 - 26
90 - 95
240 PSIG
165