Operational Characteristics: Cme506R - Scotsman CME506R Product Manual

Autoiq cubers
Table of Contents

Advertisement

CME506R, 656R, 806R: AutoIQ Cubers

Operational Characteristics: CME506R

Cycle Times (Minutes):
Freeze
Harvest
System Pressures (PSIG):
Suction: End of Freeze
Suction: Peak in Harvest
Discharge: 5 minutes into Freeze
Discharge: Minimum in Harvest
Refrigerant Charge
224 ounces of R-404A
Typical Compressor Amps
Freeze: 10 - 12
Harvest: 12- 13
Typical Harvest Ice Weight
6.5 - 7 lb.
Note: Beginning with CME506R - E series, the
refrigeration system uses 2 internally equalized
thermostatic expansion valves.
o
o
0
F. condenser air 70
F. indoor air,
o
55
F. water
21 - 24
1.5 - 2.5
o
o
0
F. condenser air 70
F. indoor air,
o
55
F. water
34 - 36
100 - 110
230 - 250
200
March 2002
Page 32
o
o
90
F. condenser air 90
F. indoor
o
air, 70
F. water
25 - 28
1 - 2
o
o
90
F. condenser air 90
F. indoor
o
air, 70
F. water
36 - 38
105 - 115
250 - 270
210