CME1356 and CME1656

Specifications

These ice machines are designed to be installed
indoors, in a controlled environment. They can
operate satisfactorily under a wide variety of
conditions. Do NOT operate the machine in
temperatures it has not been designed for. Do
NOT operate the machine above or below the
voltage limits for the particular model. Do NOT
operate the machine with too little or too much
water pressure.
Operational Limits
Air Temperature
Water Temperature
Water Pressure
Voltage (60 Hz model)
Voltage (50 Hz model)
Inlet water flow required is 2.7 GPM.
A stacking kit, for like models, is KSCME6-LG-B
Basic Information
Model
Model Number
Series
CME1356AS-32 A thru E 48 ½ x 24 x 28 208-230/60/1 Air Cooled
CME1356WS-32 A thru E same
CME1356WS-32 F
CME1356AS-3
A thru E same
CME1356WS-3
A thru E same
CME1356WS-3
F
CME1356AS-6
A thru E same
CME1356WS-6
A thru E same
CME1356WS-6
F
CME1656AS-32 A thru D same
CME1656WS-32 A thru E same
CME1656WS-32 F
CME1656AS-3
A thru E same
CME1656WS-3
A thru E same
CME1656WS-3
F
CME1656AS-6
A thru E same
CME1656WS-6
A thru E same
CME1656WS-6
F
Minimum
Maximum
o
o
50
F.
100
F.
o
o
40
F.
100
F.
20 psi
80 psi
198
253
207
253
Dimensions
Basic
W" x D" x H"
Electrical
(w/o bin)
208-230/60/1 Water Cooled
same
208-230/60/1 Water Cooled
208-230/60/3 Air Cooled
208-230/60/3 Water Cooled
same
208-230/60/3 Water Cooled
230/50/1
230/50/1
same
230/50/1
208-230/60/1 Air Cooled
208-230/60/1 Water Cooled
same
208-230/60/1 Water Cooled
208-230/60/3 Air Cooled
208-230/60/3 Water Cooled
same
208-230/60/3 Water Cooled
230/50/1
230/50/1
same
230/50/1
November 2004
Voltage note: The control system transformer in
the control box of this ice machine has two primary
taps, one for 208 volt power and one for 240 volt
power. The machine ships with the power supply
connected to the 208 volt tap. Change to the 240
volt tap when the voltage supplied to the unit is
greater than 229 volts
All models will fit a standard, 48" wide Scotsman
Ice Storage Bin. Some examples are BH900,
BH1100, BH1300, BH1600. There may be other
bins that can be used, check Scotsman's sales
literature for application information. Slope front
bins must have an internal baffle like the BH900.
Baffle must be approximately in the position shown
in the diagram on page 5.
Scotsman reserves the right to make design
changes and/or improvements at any time.
Specifications and designs are subject to change
without notice.
Dateplates on the ice machine contain charge and
electrical requirements. Always go by the dataplate
information. The table below is for reference.
Minimum
Condenser
Type
Ampacity
26.7
23.9
23.9
17.8
14.9
14.9
Air Cooled
26.7
Water Cooled
23.9
Water Cooled
23.9
26.7
23.9
23.9
17.8
14.9
14.9
Air Cooled
26.7
Water Cooled
23.9
Water Cooled
23.9
Page 2
Maximum
Refrigerant
Circuit
Fuse
Charge
Size
(R-404A)
30
64 ounces
30
62 ounces
30
58 ounces
20
64 ounces
20
62 ounces
20
58 ounces
30
64 ounces
30
62 ounces
30
58 ounces
30
64 ounces
30
62 ounces
30
58 ounces
20
64 ounces
20
62 ounces
20
58 ounces
30
64 ounces
30
62 ounces
30
58 ounces

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cme1656

Table of Contents