Technicians Only: Freeze Cycle Operational Sequence

Assuming the machine has been operational, the
Freeze cycle begins with the end of the Harvest
Cycle:
Condenser fan is OFF
Water Inlet Valve is CLOSED
Water Pump may be ON
Compressor is ON
Hot Gas Valve is OPEN
AutoIQ Controller Operation, Beginning freeze:
1. Switches on the Freeze indicator light and shuts
off the hot gas valve.
2. Opens the water valve to top off the reservoir.
Water must fill the reservoir within 250 seconds or
the controller shuts the machine down. It will
automatically try to restart in 20 minutes.
3. Measures the discharge temperature.
4. Starts the fan motor (air cooled only). The
Controller checks the discharge temperature and
cycles the fan every on for 30 seconds and off for
20 seconds if the temperature is low.
If the discharge temperature exceeds the design
maximum, shuts the machine down on a
Refrigeration Error.
5. Checks for a "bin full" signal throughout the
cycle.
6. Measures the reservoir water temperature. If the
machine is operating correctly, the reservoir water
temperature will fall at a standard rate. The AutoIQ
Controller will be checking to see if the water
temperature fall matches that rate.
If not, it re-checks the discharge line temperature.
If too low, it Shuts Down on a Refrigeration Error.
If the discharge temperature is acceptable, the
water system is checked by shutting off the water
pump and determining if the water level goes up
enough. If it does not, it is assumed that there is a
water pump problem and the machine Shuts Down
on a Water Error.
If the water level does "measure up" the water
pump is restarted and the AutoIQ Controller then
measures how long it takes to lower the water
level. If the water level does not fall, the machine
Shuts Down on a Water Error.
7. Once per cycle the machine will shut off the
water pump. It only does this when the water
temperature reaches a preset minimum. The pump
will only be off for a few seconds. After the pump
restarts, the inlet water valve opens to refill the
reservoir.
8. As the machine makes ice, the water level in the
reservoir will ultimately fall to the Harvest Level .
The first time that happens during a freeze cycle
prompts the controller to re-fill the reservoir. The
next time it happens, the unit will begin to go into a
harvest cycle.
Air cooled models will switch off the fan motor a few
seconds before harvest begins.
Note: If the freeze cycle exceeds the preset
Maximum (36 minutes), the AutoIQ Controller will
Shut Down on a Refrigeration Error.
9. At the end of Freeze cycle:
Water level = below harvest position
Condenser fan will be off
Water inlet valve will be off
Water pump will be ON
Compressor will be ON
Hot gas valve will be off
At this point Harvest begins and the AutoIQ
Controller switches the Harvest indicator light ON.
Restarts:
If restarting after shutting off because the bin was
full, the first freeze cycle sequence is like this:
1. Purge valve is open.
2. Pump starts.
3. Purge valve closes.
4. Water valve opens to fill the reservoir.
5. Compressor starts.
Note: If there is a power interruption, after power is
restored the machine will restart, go thru a brief
Freeze cycle and then go thru a 6 minute Harvest
cycle. The Freeze light will be blinking - even when
the machine is in harvest.
Error Restarts:
The machine automatically attempts to restart 50
minutes after a shut down. If another problem
occurs in the next cycle, the machine will attempt
one more restart. If another problem occurs in the
next cycle, the machine will be off and must be
manually reset.