FOR THE ELECTRICIAN

SEE NAMEPLATE for current requirements to
determine wire size to be used for electrical
hookup. The cuber requires a solid chassis to
chassis earth ground wire. See Wiring Diagram.
Be certain the cuber is connected to its own
electrical circuit and individually fused. Voltage
variation should not exceed ten percent of the
nameplate rating, even under starting conditions.
Low voltages can cause erratic operation and
may be responsible for serious damage to the ice
maker.
FOLLOW ALL APPLICALBE CODES
ELECTRICAL CONNECTIONS, WATER COOLED
CME1202 & CME1402
Electrical connections are made at the rear of
the ice maker, inside the junction box.
All external wiring should conform to the
national, state and local electrical code
requirements. Usually an electrical permit and
services of a licensed electrician will be
required.
HAND
DISCONNECT
SWITCH
JUNCTION
BOX
ELECTRICAL CONNECTIONS, AIR COOLED
January 1995
Page 7
GROUND SCREW
DETAIL OF
JUNCTION BOX