Honeywell SLN 700 User Manual page 25

Smartline level transmitter non-contact radar
Hide thumbs Also See for SLN 700:
Table of Contents

Advertisement

Programming
instruction
Programming
menu
structure
Programming
sub-menu
Basic settings
Display
Diagnosis
Advanced
settings
System
Programming
method
Parameter
editing method
Character/
number
parameter
programming
Revision 2
The four keys on the panel can be used to set parameters,
debug and test the instrument, etc.
The rightward transition to the horizontal arrow in the figure can
be achieved by the key;
The downward transition to the horizontal arrow in the figure can
be achieved by the key.
The leftward transition to the horizontal arrow in the figure can
be achieved by the key.
The basic settings include the following parameters of the
meter: Tank medium, the unit of measurement, the near
blanking distance, the range, the minimum adjustment, the
maximum adjustment, the current output and the sensor tag.
Display Value and Language settings of the meter.
Diagnose and complete the instrument inspection and test
function. For the following: Choose Curve, Show Curve, Start
Simulation, Sensor Status, Measure Status, Peak values and
Calibration Date.
Options include False Echo Memory, Failure Mode, Reset to
Factory Settings, Distance Adjust, Echo Threshold, Damping,
Envelope Level, Hart Address and Multi Drop, Damp Time, Max
Level Speed, First Echo, Multi Wave, IF Gain, Tx Power, Rx
Gain, 4 mA Adjust, 20 mA Adjust, Low DK value, Dust.
Include meter information such as Info, Software Version,
Latching Mode, Write Protect.
When the meter is running, press
programming state and display the programming main menu.
After each parameter is edited, the
confirm, otherwise the edit is invalid.
After editing, press
return to the running state.
At any time of programming, press
programming and exit the programming state of the parameter
item.
When the menu switches to changing a numeric or character
value, the first of those digits highlighted. At this point, you can
press
desired character/number appears.
SLN 700 SmartLine NCR Level Transmitter User's Manual
to exit the programming state and
key to change the character/number until the
to enter the
key must be used to
to abandon