1.4

Important Safety Instructions

Caution!
Installation must be made by qualified personnel and conform to ANSI/NFPA 70 (the National
!
Electrical Code
and all applicable local codes. Bosch Security Systems accepts no liability for any damages or
losses caused by incorrect or improper installation.
Warning!
INSTALL EXTERNAL INTERCONNECTING CABLES IN ACCORDANCE TO NEC, ANSI/NFPA70
(FOR US APPLICATION) AND CANADIAN ELECTRICAL CODE, PART I, CSA C22.1 (FOR CAN
APPLICATION) AND IN ACCORDANCE TO LOCAL COUNTRY CODES FOR ALL OTHER
!
COUNTRIES. BRANCH CIRCUIT PROTECTION INCORPORATING A 20 A, 2-POLE LISTED
CIRCUIT BREAKER OR BRANCH RATED FUSES ARE REQUIRED AS PART OF THE BUILDING
INSTALLATION. A READILY ACCESSIBLE 2-POLE DISCONNECT DEVICE WITH A CONTACT
SEPARATION OF AT LEAST 3 mm MUST BE INCORPORATED.
Warning!
ROUTING OF EXTERNAL WIRING MUST BE DONE THROUGH A PERMANENTLY EARTHED
!
METAL CONDUIT.
Notice!
i
Outdoor installation
For details about the proper configuration for installing your camera outdoors with surge and
lightning protection, refer to Best Practices for Outdoor Installation.
Notice!
Bosch recommends the use of surge/lightning suppression devices (sourced locally) to
i
protect network and power cables and the camera installation site. Refer to NFPA 780, Class
1 & 2, UL96A, or the equivalent code appropriate for your country/region, and to local
building codes. Refer also to the installation instructions of each device (midspan, camera,
and surge suppression device installed where the cable enters the building).
Notice!
Ancillary power (UPS) required
i
To meet the Mains Supply Voltage Dips and Short Interruptions requirements per EN 50130-4
Alarm Standard, ancillary equipment (for example, an Uninterruptible Power Supply (UPS)) is
necessary. The UPS must have a Transfer time between 2-6 ms and Backup Runtime of
greater than 5 seconds for the power level as specified on the product data sheet.
Bosch Security Systems
Before transporting, supply power to the camera and rotate the camera head so that the
window points toward the base. This position of the camera head will help to protect the
wiper and the window during transit.
®
(NEC)), Canadian Electrical Code, Part I (also called CE Code or CSA C22.1),
Ensure that the unit case is properly earthed. If the product is at risk of being struck by
lightning, ensure that earth bonding connections are made correctly to the mounting of
the base of the unit.