Makita MAC5200 Owner's Manual page 36

Oil lubricated air compressor
Hide thumbs Also See for MAC5200:
Table of Contents

Advertisement

For No. 1 method, set the change lever to the "Intermittent
Nailing" position. For No. 2 method, set the change lever
to the "Continuous Nailing" position. After using the change
lever to change the nailing method, always make sure that
the change lever is properly set to the position for the
desired nailing method.
Air exhaust
Air exhaust direction can be changed easily by rotating the
exhaust cover. Change it when necessary.
Intermittent
Trigger lock
nailing
Exhaust cover
-
/
Jammed nailer
CAUTION :
Always lock the trigger, disconnect the hose and remove the nails from the magazine before cleaning
a jam.
When the nailer becomes jammed, proceed as follows:
Open the door and magazine cap and remove the nail coil.
Insert a small rod or the like into the ejection port and tap
it with a hammer to drive out the nail jamming the ejection
port. Reset the nail coil and close the magazine cap and
door.
Hook
The hook is convenient for hanging the tool temporarily. This
hook can be installed on either side of the tool.
I
Hook
\
CAUTION:
*Always lock the trigger and disconnect the hose when hanging the tool using the hook.
*Always tighten the hook securing bolt firmly. Loose bolt may cause air leakage from the tool.
14