CL5808/CL5816 User Manual

Firmware Upgrade Recovery

Below are three conditions that may result in requiring a firmware upgrade
recovery:
When a firmware upgrade is manually aborted.
When the mainboard firmware upgrade fails.
When the I/O firmware upgrade fails.
To perform a firmware upgrade recovery, do the following:
1. Power off the switch. If it is part of a daisy chain, disconnect it from the
chain.
2. Connect the Firmware Upgrade Cable to its Firmware Upgrade Port.
3. Slide the Firmware Upgrade Recovery Switch to the Recover position.
4. Power the switch back on and repeat the upgrade procedure.
5. After the switch has been successfully upgraded, power it off, and slide the
Firmware Upgrade Recovery Switch back to the Normal position.
6. If the switch is part of a daisy chain, replace it in the chain.
7. Power the switch back on.