Miscellaneous - Rheem RGEA16 Installation Instructions Manual

Table of Contents

Advertisement

XIII. MISCELL NEOUS
Unit Operating
Voltage Range
Volts
Minimum Circuit
Ampacity
Minimum Overcurrent
Protection Device Size
Maximum Overcurrent
Protection Device Size
No.
Volts
Phase
RPM
HP, Compressor 1
Amps (RLA), Comp. 1
Amps (LRA), Comp. 1
No.
Volts
Phase
HP
Amps (FLA, each)
Amps (LRA, each)
No.
Volts
Phase
HP
Amps (FLA, each)
Amps (LRA, each)
1. Horsepower per Compressor
2. Amp Draw Per Motor. Multiply Value by Number of Motors to Determine Total Amps.
ELECTRICAL DATA – RGEA16 SERIES
024 JV
036 CV
036 JV
197-253
197-253
197-253
208/230
208/230
208/230
18/18
19/19
25/25
20/20
20/20
30/30
25/25
25/25
40/40
1
1
1
208/230
208/230
208/230
1
3
1
3450
3450
3450
2 5/6
4
4
11.7/11.7
11.6/11.6
16.7/16.7
58.3/58.3
73/73
83/83
1
1
1
208/230
208/230
208/230
1
1
1
1/6
1/6
1/6
0.6/0.6
0.6/0.6
0.6/0.6
1.5/1.5
1.5/1.5
1.5/1.5
1
1
1
208/230
208/230
208/230
1
1
1
1/2
1/2
1/2
2/2
2/2
2/2
0/0
0/0
0/0
048 CV
048 JV
060 CV
197-253
197-253
197-253
208/230
208/230
208/230
22/22
31/31
27/27
25/25
40/40
30/30
35/35
50/50
40/40
1
1
1
208/230
208/230
208/230
3
1
3
3450
3450
3450
5 1/4
5 1/4
7
14/14
21.2/21.2
16.5/16.5
88/88
104/104
110/110
1
1
1
208/230
208/230
208/230
1
1
1
1/3
1/3
1/3
1.5/1.5
1.5/1.5
2/2
3/3
3/3
3.9/3.9
1
1
1
208/230
208/230
208/230
1
1
1
3/4
3/4
1
3/3
3/3
4/4
0/0
0/0
0/0
060 JV
197-253
208/230
40/40
45/45
60/60
1
208/230
1
3450
6 2/3
27.1/27.1
153/153
1
208/230
1
1/3
2/2
3.9/3.9
1
208/230
1
1
4/4
0/0
45

Advertisement

Table of Contents
loading

Table of Contents