FIGURE 28

HEATING AIRFLOW ADJUSTMENTS

O
N
38
F. HE TING IRFLOW DJUSTMENTS
5
6
5
6
5
6
O
O
N
N
A
B
C
SELECTION
A
B
C
D
Heating airflow may be adjusted +10% or –10% from nominal airflow using switches 5 & 6.
Refer to Figure 28 for switch positions to achieve the desired adjustments in airflow.
NOTE: Continuous fan speed is NOT affected by switches 5 & 6.
G. COOLING DEL Y PROFILES
The unit is shipped with a default ON/OFF delay profile for maximum efficiency. This default
may be overridden to maximize comfort by using one of the alternate profiles. ON delay pro-
files are shown in Figure 26.
OFF delay profiles are shown in Figure 27.
IMPORTANT: Blower ON delay profiles are not used in heating mode.
5
6
O
N
D
SWITCH 5
SWITCH 6
POSITION
POSITION
OFF
ON
OFF
ON
HEATING
AIRFLOW
ADJUSTMENT
OFF
NONE
OFF
ON
-10%
ON
NONE
10%