Installation
ply and drain the line of any
standing water (if possible),
before proceeding to tie into
the water line.
NOTE: Once the new plumbing
!
connections are complete ensure
that the lines are flushed to prevent
any debris from going into the unit.
On the cassette, remove the
3.
top cover assemblies (Figure
8) and prime each of the water
reservoirs with 33.5 oz (1L) of
water.
Replace the top cover assem-
4.
blies and ensure that the two
plumbing caps are securely
attached to the top cover of the
water reservoirs. (Figure 8)
Locate the ball valve located
5.
in the bottom center of the unit
Figure 2
Media Plate: 12¼ in. (311mm)
Log Set: 14¼ in. (362mm)
Adjustable from
9 in. to 9 ½ in.
(229 mm to 241 mm)
8
(near the back). (Figure 1)
Attach one end of the ¼ in. (6.4
6.
mm) tubing to the ball valve.
Insert the tubing into the ball
valve fitting so that it is fully
inserted (approximately ½" (12
mm)).
NOTE: Ensure that the end of
!
the tubing is cut square, to prevent
leaking.
Route the tubing to the area of
7.
the water source.
Verify that all of the connec-
8.
tions are fully inserted, and
begin opening each of the
valves, ensuring that no leaks
are present.
NOTE: The unit is equipped
!
with three levels of water control
management.
CDFI500P: 20 ⅜ in. (518mm)
CDFI1000P: 40 ⅜ in. (1025mm)
Fresh Air Inlet
CDFI500P: 40 in
CDFI1000P: 80 in
Installation
Surface
Exit for Electrical
)
2
(258 cm
2
)
2
(516 cm
2
www.dimplex.com