Siemens SITRANS LG270 Operating Instructions Manual page 68

Guided wave radar
Table of Contents

Advertisement

Ʋ Stranded wire with end sleeve
Electromechanical data - version IP66/IP68 (1 bar)
Options of the cable entry
Ʋ Cable gland with integrated connec-
tion cable
Ʋ Cable entry
Ʋ Blind plug
Connection cable
Ʋ Configuration
Ʋ Wire cross-section
Ʋ Wire resistance
Ʋ Tensile strength
Ʋ Standard length
Ʋ Max. length
Ʋ Min. bending radius (at 25 °C/77 °F)
Ʋ Diameter
Ʋ Colour - Non-Ex version
Ʋ Colour - Ex-version
Display and adjustment module
Display element
Measured value indication
Ʋ Number of digits
Adjustment elements
Ʋ 4 keys
Protection rating
Ʋ unassembled
Ʋ Mounted in the housing without lid
Materials
Ʋ Housing
Ʋ Inspection window
Functional safety
Integrated clock
Date format
Time format
Time zone, factory setting
Max. rate deviation
68
0.2 ... 1.5 mm² (AWG 24 ... 16)
M20 x 1.5 (cable diameter 5 ... 9 mm)
½ NPT
M20 x 1.5; ½ NPT
four wires, one suspension cable, braiding, metal foil,
cover
0.5 mm² (AWG 20)
< 0.036 Ω/m
< 1200 N (270 lbf)
5 m (16.4 ft)
180 m (590.6 ft)
25 mm (0.984 in)
approx. 8 mm (0.315 in)
Black
Blue
Display with backlight
5
[OK], [->], [+], [ESC]
IP 20
IP 40
ABS
Polyester foil
SIL non-reactive
Day.Month.Year
12 h/24 h
CET
10.5 min/year
SITRANS LG270 - Operating Instructions
PBD-51041507

Advertisement

Table of Contents
loading

Table of Contents