Access & Removal

Control Panel Removal:

1)
Drawer Microwave must be removed from its
installation. See Drawer Microwave Disassembly
(page 4-6) steps 1-3.
DISCONNECT ELECTRICAL SUPPLY BEFORE
ATTEMPTING THE FOLLOWING PROCEDURES.
DANGEROUS HIGH VOLTAGE CAN BE PRESENT -
CAREFULLY READ AND FOLLOW ALL WARNINGS AT
THE BEGINNING OF THIS SECTION. (PAGE 4-2)
2)
Using a phillips screw driver, remove 3 screws (ea.
side) that fasten drawer mounting brackets to unit
and set brackets aside until reassembly (Figure 4-7)
3)
Locate and remove 3 screws (1 right side - 2 on left
side) that fasten control panel to the front frame of
unit. (Figure 4-8)
4)
Carefully lift control panel off.
5)
If control panel is being replaced, transfer connectors
one at a time to new control panel to insure proper
connection. (Figure 4-9)
NOTE: For Control Panel Testing/Servicing Procedures
see Page 4-5.
NOTE: PLEASE SEE "AFTER SERVICING" (Page 4-6)
WHEN REPAIR COMPLETE.

Cavity Light Replacement:

1)
Drawer Microwave must be removed from its
installation. See Drawer Microwave Disassembly
(page 4-6) steps 1-3.
2)
Locate and remove lamp access panel in top plate.
(Figure 4-3)
DISCONNECT ELECTRICAL SUPPLY BEFORE
ATTEMPTING THE FOLLOWING PROCEDURES.
DANGEROUS HIGH VOLTAGE CAN BE PRESENT -
CAREFULLY READ AND FOLLOW ALL WARNINGS AT
THE BEGINNING OF THIS SECTION.
Wear gloves when handling sheet metal parts, sheet
metal edges may be sharp.
NOTE: Lamp and socket are an assembly. You must
change socket with lamp.
3)
Remove lamp socket screw to remove lamp
assembly and replace with new. (Figure 4-10)
Drawer Microwave
4-8
Figure 4-7 Drawer Mounting Bracket
(Right side pictured)
Right Side
Screws
Figure 4-8 Control Panel Screws
Figure 4-9 Control Panel Connectors
Screw
Figure 4-10 Lamp & Socket Removal