I/O Circuit Diagrams

NPN Amplifier Unit: ZX-LDA11
Current output
4 to 20 mA
Current/voltage
switch
Voltage output
±4V
100 Ω
Connections: Amplifier Unit
Note 1. Use a separate stabilized power supply for the Amplifier Unit,
particularly when high resolution is required.
2. Wire the Unit correctly. Incorrect wiring may result in damage to
the Unit. (Do not allow wiring, particularly the linear output, to
come into contact with other lines.)
3. Use the 0-V line (blue) for the power supply and use the shield
wire (linear output ground) together with the linear output (black
line) for linear output. Each of these grounds must be used for
the designed purpose. When not using the linear output, con-
nect the linear ground (shield) to the 0-V ground.
ZX Series (ZX-L)
12
Brown: 12 to 24 VDC
White: HIGH
output
Green: PASS output
12 to
24 VDC
Gray: LOW output
Blue: GND (0V)
Pink: Laser OFF input
Purple: Timing input
Orange: Zero reset input
Red: Reset input
Black: Linear output
Current output: 300 Ω max.
Voltage output: 10 kΩ min.
Shield: Linear GND
Brown:
12 to 24 VDC
Blue:
GND (0V)
White:
HIGH output
Green:
PASS output
Gray:
LOW output
Black:
Linear output
Shield:
Linear output GND
Pink:
Laser OFF input
Orange:
Zero reset input
Purple:
Timing input
Red:
Reset input
Smart Sensors
PNP Amplifier Unit: ZX-LDA41
Current output
4 to 20 mA
Current/voltage
switch
Voltage output
±4V
100 Ω
Brown: 12 to 24 VDC
White: HIGH output
Green: PASS output
12 to
24 VDC
Gray: LOW output
Blue: GND (0V)
Pink: Laser OFF input
Purple: Timing input
Orange: Zero reset input
Red: Reset input
Black: Linear output
Current output: 300 Ω max.
Voltage output: 10 kΩ min.
Shield: Linear GND