Rangemaster Longstock 90 Induction User's Manual & Installation Instructions page 6

Table of Contents

Advertisement

Fig. 1.1
L
N
10 mm² max
ArtNo.130-0010 Electrical connections single-phase
230 V ac 50 Hz
Fig. 1.2
L1
N
L3
L2
6 mm² max
3N ac
230/400 V 50 Hz
n
Access to the mains terminal is gained by
removing the electrical terminal cover box on
the back panel. Connect the mains cable to the
correct terminals for your electrical supply type
(Fig. 1.1 and Fig. 1.2). Check that the links are
correctly fitted and that the terminal screws are
tight. Secure the mains cable using the cable
6 mm² max
clamp.
Minimum temperature rating T105
Read the instructions before installing or using
this appliance.
6 mm² max
10 mm² max
2
The cooker MUST NOT be connected to
an ordinary domestic power point.
This appliance is heavy so take care when
moving it.
The cable size and type should be suitable
for the Electrical Load of the appliance and
comply with the relevant national and local
requirements.
The cooker may be installed in a kitchen/
kitchen diner but NOT in a room
containing a bath or shower.
The cooker MUST NOT be connected to an
ordinary domestic power point.
It is normal for the hob control display
to flash for about 2 seconds during first
power setting.
Set the clock to make sure that the oven is
functional – see the relevant section in this
manual.
The appliance must be installed in
accordance with the regulations in force
and only in a well ventilated space.
Failure to install the appliance correctly
could invalidate any warranty or liability
claims and lead to prosecution.
DO NOT install the appliance on a
platform.
DO NOT manouvre the cooker while it is
plugged into the electricity supply.

Advertisement

Table of Contents
loading