Fujitsu Comfort Series Service Manual page 54

Hide thumbs Also See for Comfort Series:
Table of Contents

Advertisement

SERVICE PARTS INFORMATION 5
Thermistor
Check Point : Check Thermistor resistance value
Remove connector and check Thermistor resistance value.
Temperature
[°C]
Thermistor A
-30
1013.1
-20
531.6
-10
292.9
0
168.6
10
100.9
20
62.5
30
40.0
40
26.3
50
17.8
60
12.3
70
8.7
80
6.3
90
4.6
100
3.4
110
2.6
120
2.0
130
140
150
Applicable
Discharge temp. TH
Thermistors
Compressor temp. TH
Ex. valve temp. TH
Resistance Value [ k ]
Thermistor B
95.6
50.3
27.8
16.1
9.6
6.0
3.8
2.5
1.7
1.2
0.8
0.6
---
---
---
---
---
---
---
---
---
---
Heat exchanger. TH
Thermistor C
Thermistor D
224.3
94.3
115.2
49.6
62.3
27.4
35.2
15.8
20.7
9.5
12.6
5.9
8.0
3.8
5.2
2.5
3.5
1.7
2.4
1.2
---
0.8
---
0.6
---
0.4
---
0.3
---
0.2
---
0.2
---
0.1
---
0.1
---
0.1
Outdoor temp. TH
Heatsink temp. TH
03-35