Troubleshooting 3
HYDRAULIC UNIT Error Method:
Combination error
Detective Actuators:
Hydraulic unit
Forecast of Cause:
1. The combination of hydraulic unit and outdoor unit is incorrect
Check Point 1 : Check the type of hydraulic unit
Check the type of the connected hydraulic unit and outdoor unit.
>> If abnormal condition is found, correct it.
OK
Check Point 2 : Replace Main PCB
If Check Point 1 do not improve the symptom, replace Main PCB of Outdoor unit.
Indicate or Display:
Hydraulic unit :
Green Red
2
3
n : n times blinking
Detective details:
1. The outdoor unit receives the serial signal of applied refrigerant
information from hydraulic unit. When the refrigerant is R410a.
2. The combination of hydraulic unit and outdoor unit isn't allowed.
03-05
Outdoor unit :
Mode Error L1 L2
L3
L4
2
2
3
: Light OFF
: Light ON
n : n times blinking
L5
L6