DRY • COOL• FAN Operation
The air conditioner operates with the operation mode of your choice.
From the next time on, the air conditioner will operate with the same operation mode.
■ To start operation
Press (M ooE ] select an operation mode.
• Each pressing of the button changes the mode setting.
1- Ill -- * ---+ ,t
l° RY
COOL
■ Cool
• In this mode compressor will switch on after a delay of about three
minute depending on the differential of Room Temp & Set
Temperature.
• Preset temperature (from18
um/high/auto) can be changed by the user.
• Fan Speed Can be Selected (Auto, High, Medium or Low).
• Compressor will work as per the following conditions:
Compressor will cut off,
If Room temperature= Preset temperature - 1. s
Compressor will cut in,
If Room temperature= Preset temperature+ 1
■ Dry
In this mode
• Fan speed will be Auto .
• Set temperature = Room temperature - 2
• Compressor works as per cool mode.
■ Fan
• In this mode, Compressor will be switched off.
• Auto, High, Medium or Low Fan speed can be selected with
Fan key.
7
FAN�
°
C to 32
°
C) and fan speed (low/medi­
°
C or Below.
°
C or Above.
°
C.