Safety Precautions
Keep this manual where the user can easily find it.
Read the precautions in this manual carefully before operating
the unit.
The precautions described herein are classified as WARNING
and CAUTION. They both contain important information
regarding safety. Be sure to observe all precautions without fail.
&WARNING
Failure to follow these instructions properly may result in
personal injury or loss of life.
&CAUTION
Failure to observe these instructions properly may result in
property damage or personal injury, which may be serious
depending on the circumstances.
(9
Never attempt.
Q
Be sure to follow the instructions.
• Be sure to establish an earth connection.
• After reading, keep this manual in a convenient place so that you
can refer to it whenever necessary. If the equipment is transferred to
a new user, be sure also to hand over the manual.
&WARNING
In order to avoid fire, explosion or injury, do not operate ,::;:\
the unit when harmful, among which flammable or
corrosive gases, are detected near the unit.
Be aware that prolonged, direct exposure to cool air from the
air conditioner, or to air that is too cool can be harmful to your
physical condition and health.
Do not place objects, including rods, your fingers, etc., in the air
inlet or outlet. Product malfunctioning, product or injury damage
may result due to contact with the air conditioner's high-speed
fan blades.
Do not attempt to repair, dismantle, reinstall or modify the air
conditioner yourself as this may result in water leakage, electric
shocks or fire hazards.
Do not use flammable spray near the air conditioner, or
otherwise fire may result.
Do not use a refrigerant other than the one indicated on the
window AC unit (R32) when installing, moving or repairing.
Using other refrigerants may cause trouble or damage to the
unit, and personal injury
To avoid electric shocks, do not operate with wet hands.
Beware of fire in case of refrigerant leakage. If the air
conditioner is not operating correctly, i.e. not generating
cool air, refrigerant leakage could be the cause. Consult
your dealer for assistance. The refrigerant within the air
conditioner is safe and normally does not leak.
However, in the event of a leakage, contact with a naked
burner, heater or cooker may result in generation of noxious
gas. Do not use the air conditioner until a qualified service
person confirms that the leakage has been repaired.
Do not attempt to install or repair the air conditioner yourself.
Improper workmanship may result in water leakage, electric
shocks or fire hazards. Please contact your local dealer or
qualified personnel for installation and maintenance work.
When the air conditioner is malfunctioning (giving off a burning
odour, etc.) turn off power to the unit and contact your local
dealer. Continued operation under such circumstances may
result in a failure, electric shocks or fire hazards.
Be sure to earth the unit. Do not earth the unit to a
utility pipe, lightning conductor or telephone earth lead.
Imperfect earthing may result in electric shocks.
&CAUTION
Do not use the air conditioner for purposes other than those for
which it is intended. Do not use the air conditioner for cooling
precision instruments, food, plants, animals or works of art as
this may adversely affect the performance, quality and/or
longevity of the object concerned.
Do not expose plants or animals directly to airflow from the unit
as this may cause adverse effects.
Do not place appliances that produce naked flames in places
exposed to the airflow from the unit as this may impair
combustion of the burner.
Do not block air inlets or outlets. Impaired airflow may result in
insufficient performance or trouble.
Do not sit on the window AC unit, put things on the unit, or pull
the unit. Doing so may cause accidents, such as falling or
toppling down, thus resulting in injury, product malfunctioning,
or product damage.
Do not place objects that are susceptible to moisture directly
beneath the window AC units.
After prolonged use, check the unit stand and its mounts for
damage. If they are left in a damaged condition, the unit may fall
and cause injury.
To avoid injury, do not touch the air inlet or aluminium fins of the
window AC unit.
The appliance is not intended for use by unattended young
children or infirm persons. Impairment of bodily functions and
harm to health may result.
Children should be supervised to ensure that they do not play
\::,I
with the unit or its remote controller. Accidental operation by a
child may result in impairment of bodily functions and harm
health.
Avoid impacts to the window AC unit, or otherwise product
damage may result.
Do not place flammable items, such as spray cans, within 1 m
of the air outlet.
Be careful not to let pets urinate on the air conditioner. Urination
on the air conditioner may result in electric shocks or fire.
Do not place water containers (vases etc.) above the unit, as
this may result in electric shocks or fire hazards.
To avoid oxygen depletion, ensure that the room is
adequately ventilated 1f equipment such as a burner is
used together with the air conditioner.
Before cleaning, be sure to stop unit operation, turn off the
circuit breaker or remove the power cord. Otherwise, an electric
shock and injury may result.
Only connect the air conditioner to the specified power supply
circuit. Power supplies other than the one specified may result
o
in electric shocks, overheating and fires.
Arrange the drain hose to ensure smooth drainage. Imperfect
drainage may cause wetting of the building, furniture etc.
Do not place objects around the window AC unit. Doing so may
have an adverse influence on the performance, product quality,
and life of the air conditioner.
This appliance is not intended to be used by persons with
reduced physical, sensory or mental capabilities, or with lack of
operation knowledge, unless they have been given supervision
or instruction concerning the appliance use by person
responsible for their safety.
Keep out of children's reach to ensure that they do not play with
the appliance.
e
o

Advertisement

Table of Contents
loading

Summary of Contents for Daikin FRWKL50UV163A

  • Page 1 DAIKIN OPERATION MANUAL (The Installation Manual is on the back side.) MODELS: FRWKL50UV163A, FRWKF50UV163A, FRWKL60UV163A Safety Precautions dealer. Continued operation under such circumstances may result in a failure, electric shocks or fire hazards. Be sure to earth the unit. Do not earth the unit to a Keep this manual where the user can easily find it.
  • Page 2: Name Of Parts

    Read before Operation Name of Parts Front Grille Air Filter Remote Control Cabinet Air Inlet Grille {Outdoor Side) Air Outlet Grille Electronic Control Keypad ® Power Supply Cord Horizontal Deflectors Power supply cord conductors are distinguished according to color For your safety and protection, this unit is earthed through the power supply cord.
  • Page 3: Remote Controller

    Display (LCD) Displays the current settings. (In this illustration, each section is shown with all its displays on for the purpose of explanation.) �DAIKIN ON/OFF button Press this button once to start operation. Press once again to stop it. Signal transmitter...
  • Page 4: Preparation Before Operation

    Read before Operation Preparation before Operation To set the batteries ■ • Remove the back cover by sliding and then slightly lifting it. • Set 2 dry batteries (AAA). • Return the back cover to the pervious position. To operate the remote controller ■...
  • Page 5: General Features

    Operation WRAC CONTROLLER Operation ECONO TEMP POWER ON/OFF COOL � TIMER ■ GENERAL FEATURES: • T he controller receiver has following general features • ° ° Preset temperature setting from 18 C to 32 • Visual indication of the system configuration using LEDs and seven segment display.
  • Page 6 ■ ■ ■ Operation Dual Digit Display Dual Digit Display T he Dual digit display shows • Set Temperature in Cool and Dry mode. • Blank in standby (off) mode. • CL, dH or FA for Cool, Dry or Fan mode for 5 seconds. •...
  • Page 7: Dry • Cool• Fan Operation

    Operation DRY • COOL• FAN Operation The air conditioner operates with the operation mode of your choice. From the next time on, the air conditioner will operate with the same operation mode. ■ To start operation Press (M ooE ] select an operation mode. •...
  • Page 8: Modes Of Operations

    Operation Modes of Operations ■ Default Set Temperature Setting As per BEE regulation, whenever Air Conditioner will be switched ON from the remote, the default set temperature will be set as mentioned in below table: Mode Set temperature befor Set temperature after remote switched OFF remote switched ON ·c...
  • Page 9: Additional Features

    ■ ■ Operation Additional Features Auto fan speed While increasing room temp in Cool Mode: ° • Low fan change to medium when room temp . .?: set temp. + 2 ° • Medium fan change to high when room temp . .?: set temp.+ 4 While decreasing room temp in Cool Mode: •...
  • Page 10 Operation Additional Features ■ DelayTime • Compressor will take about 3 min time delay when ON/OFF button is pressed soon after operation is stopped or the mode is reselected. • Compressor will take about 3 minutes time delay after power ON from mains power supply.
  • Page 11 ■ Operation Additional Features ■ Notes on POWER CHILL operation • When using POWER CHILL operation, there are some functions which are not available . • POWER CHILL operation can only be set when the unit is running_ • POWER CHILL operation will not increase the capacity of the air conditioner if the air conditioner is already in operation with its maximum capacity demonstrated.
  • Page 12: Good Sleep Operation

    ■ ■ Operation Additional Features ■ To combine ON TIMER and GOOD SLEEP OFF TIMER • A sample setting for combining the 2 timers is shown below. 1 � 1 • "ON" and "OFF" are displayed on the LCD. � NOTE ■...
  • Page 13 Operation Additional Features To cancel GOOD SLEEP OFF TIMER operation P re ss (cA Nc ELJ • "0 ", "OFF" and the stop time indication disappear from the LCD. • The GOOD SLEEP lamp goes off. NOTE ■ Notes on GOOD SLEEP TIMER operation •...
  • Page 14: Troubleshooting

    • A splashing sound indicating condensed water splashing on the condenser coil. If you hear other noises please consult Daikin Authorized Service Centre. Case 2. If the unit does not operate • The main power cord is not plugged in.
  • Page 15 Troubleshooting Troubleshooting Case 5. Operation stopped suddenly • To protect the system, the air conditioner may stop operating after sudden large voltage fluctuations. • It automatically resumes operation in about 3 minutes. • Voltage Range Protection: 145V~275V Case 6. The indoor unit gives out odour •...
  • Page 16 Troubleshooting Troubleshooting Check again Please check again before requesting repairs. Explanation Case The air conditioner Has the circuit breaker been tripped or the fuse blown? does not operate. Is there a power failure? are batteries set in the remote controller? Is the timer setting correct? The room does not Is the airflow rate setting appropriate?
  • Page 17 Troubleshooting Troubleshooting Call your service centre immediately. WARNING ■ When an abnormality (such as a burning smell) occurs, stop operation and turn off the circuit breaker. Continued operation in an abnormal condition may result in problems, electric shock or fire. Consult the service centre where you bought the air conditioner.
  • Page 18 • To cancel the code display, hold down (CANCEL) for about 5 seconds (for remote display)_ The code display also c ancels itself if the button is not pressed for 1 minute (F or unit and remote display)_ DAIKIN INDUSTRIES, LTD. Head office:...
  • Page 21 ■ How to set the different addresses. When 2 window inverter units are installed in one room, the 2 wireless remote controllers can be set for different addresses. Change the address setting of one of the two units. When cutting the jumper (J4) be careful not to damage any of the surrounding parts. 1) Remove the battery cover on the remote controller and cut the address jumper (J4).
  • Page 22: Cleaning Of Air Filter

    CLEANING OF AIR FILTER 1. Lift up the inlet grill and pull 2. Wash the air filter with water or clean them out the air filter as shown below. with a vacuum cleaner. If the dust does not come off easily, wash them with neutral detergent thinned with lukewarm water, then let them dry in the shade.
  • Page 23: Care And Cleaning

    • A dirty unit may produce foul odours and dust may clog the dehumidifying drainage. • Seasonal inspection is recommended in addition to regular cleaning. • Consult Daikin Authorized Service Centre. NOTE For cleaning, do not use any of the following: °...
  • Page 24 REMOVAL OF FRONT GRILL 2. Remove the front grill. 1 . Open the screw from left and right Then open the left and right side locks side of front grill. of front grill with the cabinet. Screw at this location 3.
  • Page 25 CONDENSED WATER DRAINAGE DRAIN WANRN To achieve maximum cooling efficiency, the airconditioner is designed to splash the condensation water on the condenser coil. In order to avoid the splashing sound, an external drain can be provided by using the following procedure. T his may however cause a small loss of performance.
  • Page 26 ACCESSORIES Par t Qt y Part Q t y ® (£) Dmin Pan (Drip Tray) r,x,ng Screw M'1x1 o @ Rear Side Drain Cap @ Wirele&s remote conlroller © Operal,on/ln•tallalion manual @ E·waste (guidelines) ® Product warranty INSTALLATION OF FRONT GRILL 2.Then put the lock on the top of 1.
  • Page 27: Installing The Unit

    WINDOW AC UNIT INSTALLATION GUIDELINES INSTALLING THE UNIT For testing purpose and enhanced performance use the Installation guidelines given below • The unit should be inclined 15-20mm (0.6-0.8 Inches) towards the back for optimum perfor­ mance • For optimum performance drain should be plugged.
  • Page 28: Safety Precautions

    DAIKIN 3P604245-3E M22P112 DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL SAFETY PRECAUTIONS • The precautions described herein are classified as WARNING and CAUTION . They both contain important information regarding safety. Be sure to observe all precautions without fail. • Meaning of WARNING and CAUTION notices.