Ariston ALTEAS X FF Manual page 73

Wall hang boiler
Table of Contents

Advertisement

Training manual ALTEAS X and GENUS X
2
3
CENTRAL HEATING-1
Absolute maximum heating
2
3
0
Maximum heating power
2
3
1
(heating absolute maximum
power percentage) (%)
2
3
5
Select of heating delay manage
Heating delay (min), enabled by
2
3
6
2
3
7
Heating post-circulation (min)
2
3
8
Pump modulation on heating
ΔT for pump modulation (°C)
2
3
9
2
4
CENTRAL HEATING-2
Heating circuit minimum
2
4
0
pressure (0,x bar)
Heating circuit pressure
2
4
1
required to request filling (error
message) (0,x bar)
2
4
3
Heating post-ventilation
2
4
4
Boost time (min)
2
4
5
Max PWM pump
2
4
6
Heating water pressure
2
4
7
External temperature correction
2
4
9
2
5
DOMESTIC HOT WATER
2
5
0
Sanitary comfort function
2
5
1
Comfort anticycle (min)
Sanitary delay start
2
5
2
(anti water hammering) (dec)
2
5
3
Sanitary switch off logic
Sanitary post-circulation and
2
5
4
Heating start delay after sanitary
2
5
5
2
6
BOILER MANUAL SETTING
2
6
0
Manual mode activation
Boiler pump control
2
6
1
(set parameter 260 =1)
power
par. 2 35= 0
Min PWM pump
detection device
(°C)
post-ventilation
(min)
0 ÷ 100
0 ÷ 100
0: manual
(set with par. 2 36)
1: automatic
0 ÷ 7
0 ÷ 15
CO: non stop
0: speed 2 steady
1: speed 3 steady
2: modulating
10 ÷ 30
3 ÷ 4
Par. 240 ÷ 8
0: 5 sec
1: 3 min
0 ÷ 60
(with Auto function working)
75 ÷ 100
40 ÷ Par.245
0: temperature probes only
1: pressure switch
2: pressure sensor
-3 ÷ 3
0: disabled
1: enabled for 30 minutes after a heating request
2: always enabled
0 ÷ 120
5 ÷ 200
0: anti-scale (62 o 65°C).
1: set-point+4°C
0:
Post-ventilation: Tflow<75°C = no post-
ventilation; Tflow>75°C = 3 min (minimum
speed); Post-circulation: 30sec
1:
Post-ventilation: 3min
Post-circulation: 3min
0 ÷ 30
0: Off
1: On
0: Off
1: On (timed 10 min)
the boiler
See gas
table
See gas
table
1
3
3
2
20
4
6
0
16
100
40
2
0
0
0
5
0
0
0
0
0
Pag. 73 di 84