Ariston ALTEAS X FF Manual page 28

Wall hang boiler
Table of Contents

Advertisement

Training manual ALTEAS X and GENUS X
3 WAY VALVE MOTOR DISASSEMBLY:
Before disassembly the 3 way valve is mandatory remove the stepper motor.
To remove the stepper motor the 3 way valve must be in DHW or stand-by position, otherwise it is not
possible remove it. To do this it is enough switch off the boiler throught the ON/OFF button.
-
Remove the motor blocking ring, rotating clockwise.
-
Unblock the stepper motor
BLOCKED
UNBLOCKED
Pag. 28 di 84