Table of Contents

Advertisement

2.
Place the cylinder on the bracket in the recess compart-
ment or housing and secure them so the outlets of the
cylinder valves are facing the "sidewalls" of the com-
partment or housing (opposite of each other).
3.
Mount the regulator on the center back wall of the com-
partment or housing so the vent is pointed downward.
Attach the 1/4" inverted flare x 18" Type-1 pigtail hose
4.
to the regulator inlet and the right hand swivel nut to the
cylinder valve.
Main Supply Hose – Low Pressure
Attach the main supply hose from the regulator to the brass
manifold fitting in the frame of the trailer. The swivel brass
nut on the main hose will be your final attach-
ment.
Each time the propane container is removed:
Check that ALL fittings are tight.
1.
2.
Check that ALL connections are tested with a propane leak detector (or soapy water)
solution.
Open the main valve slowly to avoid a fast rush of propane to the excess flow valve
3.
causing propane freeze up. If you experience a propane "freeze-up," close the main
valve and wait at least fifteen (15) minutes before trying again. Refer to the regulator
manufacturer's operator manual.
4.
Listen carefully - a "hissing" sound longer than one second may indicate a propane
leak. If you feel there may be a leak present, close the valve and contact your dealer or
qualified propane technician for repair assistance.
Replace all protective covers and caps on the propane system after filling. Make sure the
valve is closed and the compartment door is securely latched.