PANEL ALERT
TYPE OF PROBLEM
The temperature of the pellets hopper or the
A03 Thermostat
water temperature exceed the envisioned
alarms
safety threshold.
A04
Smoke overheating.
A05 Pressure
Flue gas pressure switch trip.
switches alarm
A08
Abnormal smoke fan operation.
A09
Smoke probe faulty.
Routine maintenance alert (it does not block
SERVICE
the system).

11.12 ALARM RESET

To reset the alarm you must keep the 1 (ESC) button pressed for some time. The stove performs a check to determine whether the
warning cause is still present.
If this is the case, the warning will be shown again, otherwise the stove will switch to the OFF position.
If the warning is still present, contact a service centre.
12

ROUTINE MAINTENANCE

12.1 INTRODUCTION

For a long working life of the stove, have a periodic cleaning of the stove as described in the following paragrafs.
• Fume outlet pipes (fume conduit + chimney flue + chimney pot) must always be cleaned, scrubbed and checked by an autho-
rized technician in compliance with local regulations, with the instructions of the manufacturer and those of your insurance
company.
• If there are no local regulations and no instruction from your insurance company, it is necessary to have your fume pipe, chim-
ney flue and chimney pot cleaned at least once a year.
• It is also necessary to have the combustion chamber, motors and fans cleaned and to have the gaskets and the electronical
elements checked at least once a year.
All these operations must be planned in time with your Autorized Technical Assistance Service.
• After a long ineffective time, before turning on the stove check if there are obstructions in the fume exhaust.
• If the stove had been using continuously and intensely, the whole system (chimney included), must be cleaned and checked
more frequently.
• In case of replacement of damaged pieces please ask for the original spare part at the Autorized Retailer.

12.2 BEFORE EACH START-UP

Clean the ash and any deposits in the brazier that could clog the air passage holes.
If the pellets in the hopper finish, unburned pellets may accumulate in the brazier. Always empty the residue in the brazier before
startingup.
Stufe a pellet
SOLUTION
Wait for the cooling stage to end, cancel the alarm and
restart the boiler setting the fuel loading at minimum
(SETTINGS menu - Pellet Recipe).
Check that dust does not clog the aeration grid on the
stove back.
If the alarm persists, contact the service centre. Check
if the room fan works properly (if present).
The set smoke threshold has been exceeded. Reduce
pellets loading (SETTINGS menu - Pellet Recipe).
Check for chimney obstructions/fire door opening, pel-
let tank opening, gasket seals, side fire ducts cleaning,
clogged hose connection, excess flue length, unfavou-
rable weather conditions and clogged stove.
If the alarm persists, contact the service centre.
If the alarm persists, contact the service centre.
When this flashing message appears upon start-up, it
means that the preset operating hours have elapsed
before maintenance. Contact the service centre.