3.3

Wiring

1.
For the wiring, strip off the sheath of a cable, and use it with a crimp terminal. For a single wire, strip off the sheath of the
wire and apply directly.
Insert the crimp terminal or the single wire into a socket of the terminal.
Strip the signal wires as follows. If too much of the wire is stripped, a short circuit may occur with neighboring wires. If not
enough of the wire is stripped, wires may become loose and fall out. Twist the stripped end of wires to prevent them from
fraying. Do not solder them. Use a crimp terminal as necessary.
Wire strip length
L (mm)
Terminals A, B, C
6
Other than the above
5
L
3
33