SiUS092230EA

1. Indoor Unit

1.1

FTXR09/12/18WVJUW(S)9

Control PCB
1)
(A1P)
2)
3)
4)
5)
6)
7)
8)
9)
10)
11)
12)
13)
14)
H1
FG
F1U
V1
Caution
Replace the PCB if you cut a jumper unintentionally.
Jumpers are necessary for electronic circuit. Improper operation may occur if you cut any of them.
Part 3 Printed Circuit Board Connector Wiring Diagram
S21
Connector for centralized control (HA)
S25
Connector for INTELLIGENT EYE sensor PCB (A3P)
S32
Wire harness for indoor heat exchanger thermistor (R2T)
S41
Connector for swing motors
S42
Wire harness for reduction motor (front panel mechanism) and
limit switch
S46
Connector for display/signal receiver PCB (A2P)
S200
Connector for DC fan motor
H1, H2, H3
Wire harness for terminal strip (indoor - outdoor transmission)
FG
Wire harness for terminal strip (frame ground)
JB
Jumper for fan speed setting when compressor stops for
thermostat OFF
Refer to page 213 for details.
JC
Jumper for power failure recovery function (auto-restart)
Refer to page 213 for details.
LED A
LED for service monitor (green)
F1U, F2U
Fuse (3.15 A, 250 V)
V1
Varistor
H2
H3
F2U
S32
S200
S41
S21
LED A
S25

Indoor Unit

S42
JB
JC
S46
2P357399-6
25