Field Settings for FTXR Series

4. Field Settings for FTXR Series

4.1

Temperature Display Switch

Procedure
 Press the upper side of Temp button and On button at the same time for 5 seconds to change
4.2

When 2 Units are Installed in 1 Room

Outline
When 2 indoor units are installed in 1 room, 1 of the 2 indoor units and the corresponding wireless
remote controller can be set for different address.
Indoor Unit PCB
1. Remove the front grille.
2. Remove the shield plate of the electrical box.
3. Cut the address setting jumper JA on the PCB.
Caution
Replace the PCB if you cut a jumper unintentionally.
Jumpers are necessary for electronic circuit. Improper operation may occur if you cut any of them.
212
the unit of temperature display.
(R22009)
ADDRESS : JA
EXIST : 1
CUT : 2
JA
(Bottom of electrical box)
(R21128)
Part 7 Trial Operation and Field Settings