• Lead the network cables from the outside through the released swivel nut and the cable
gland into the inverter.
• For each network cable, remove one of the
filler plugs from the seal and retain for later
decommissioning.
• Lead the network cables through the swivel nut
and into the seal. The network cable plugs must
lead to the network ports in the inverter.
• Press the seal into the cable gland. Make sure that any unused cable openings are sealed
with filler plugs.
• Screw the swivel nut of the cable gland on loosely.
• Insert the network cables into the network ports. This can be done in any order.
• Fasten the swivel nut on the cable gland hand-tight. This will fix the network cables in place.
6. Flip the display down and fasten it hand-tight with the screw.
7. Close the inverter (see inverter installation manual).
8. In a small-scale PV system, depending on the system topology connect one or more inverter(s)
directly to the router.
9. In a large-scale PV power plant with Cluster Controller, connect the Cluster Controller to the
Speedwire network in accordance with the required network topology (see the
Cluster Controller installation manual).