I Feel Function; Night Function; Drain Pump Mode - Technibel CAF258C5TAA Service Manual

Table of Contents

Advertisement

4-7 I FEEL Function

As standard configuration the air conditioner operates detecting the room temperature through the sensor
equipped in the wireless remote controller (icon I FEEL shown on the display). This feature provides a
personalised environment since the temperature can be detected where the remote controller is located.
It is possible to de-activate this option pressing the I FEEL button on the remote controller.
In this case the I FEEL icon is no longer displayed and room temperature is detected through the sensor
included in the indoor unit.

4-8 NIGHT Function

When this function is active, room temperature changes automatically to compensate for body temperature
variations while sleeping. After 10 hours of operation system switches automatically to OFF state.

4-9 DRAIN PUMP Mode

This unit is equipped with a drain pump
The level detection is done through a float switch connected at the input WS (closed under normal condition,
and opened when water overflow). System operation is according to the following chart:
Open
Closed
ON
OPERATION
OFF
led
Blink
ON
CM
FMO
OFF
ON
Thermostat
OFF
ON
Drain
pump
OFF
Overflow when
THERMO is ON
15
Overflow when
Overflow when
THERMO is OFF
unit is OFF(standby)
T < 10 min