Mounting the Access Point

Note
• Operating temperature:
Note
• Console access using the console port
Note
We recommend that you make a site map showing access point locations so that you can record the device
MAC addresses from each location and return them to the person who is planning or managing your wireless
network.
Mounting the Access Point
Cisco Catalyst Wireless 9166I Series Wi-Fi 6E Access Point can be mounted in the following places:
• Suspended ceiling
• Hard ceiling
• Wall
• Electrical or network box
• Above a suspended ceiling
• Desk mount
For detailed instructions on mounting the AP, see the Access Point Mounting Instructions document at:
Cisco Catalyst Wireless 9166I Series Wi-Fi 6E Access Point Hardware Installation Guide
20
• The Underwriter Laboratories (UL)-approved Listed Power Adapter must
meet the following minimum specifications: Rated output of 42.5 to 57 Vdc,
min. 1.11A, Tma of 50°C minimum, altitude of 3048m minimum.
• If 802.3af is used, all the radios get switched off. Ethernet gets downgraded
to 1 GbE. The USB port is also off.
• CW9166I: 32°F to 122°F (0°C to 50°C)
When installing the AP in an environment where the ambient temperature is in
the range of 104°and 122°F (>40° and 50°C), the access point configuration
changes from 4x4 on the 5-GHz radios, and the uplink Ethernet will downgrade
to 1 GbE. However, the USB port remains enabled.
We recommend that you use a console cable that is one meter or less in length.
The AP may face issues while booting if you use an unterminated console cable
(not plugged into any device or terminal) or a console cable that is more than one
meter in length.
Installation Overview