Installing The Switch; Selecting A Site - SMC Networks SMC6824M Installation Manual

24-port fast ethernet switch
Hide thumbs Also See for SMC6824M:
Table of Contents

Advertisement

I

Selecting a Site

TigerStack III 10/100 units can be mounted in a standard 19-inch
equipment rack or on a flat surface. Be sure to follow the guidelines below
when choosing a location.
◆ The site should:
◆ Make sure twisted-pair cable is always routed away from power lines,
fluorescent lighting fixtures and other sources of electrical
interference, such as radios, transmitters, etc.
◆ Make sure that a separate grounded power outlet that provides 100 to
240 VAC, 50 to 60 Hz, is within 2.44 m (8 feet) of each device and is
powered from an independent circuit breaker. As with any equipment,
using a filter or surge suppressor is recommended.
NSTALLING THE
be at the center of all the devices you want to link and near a
power outlet.
be able to maintain its temperature within 0° to 50° C
(32 to 122° F) and its humidity within 10% to 90%,
non-condensing
provide adequate space (approximately two inches) on all sides for
proper air flow
be accessible for installing, cabling and maintaining the devices
allow the status LEDs to be clearly visible