Bradford White RE2H50S 1NCTT Series Installation/Operation Instruction Manual page 19

Heat pump water heater
Table of Contents

Advertisement

Electrical Connections cont.-
Branch Circuit Sizing Guide
Total Water
Protection (fuse or circuit breaker
Heater Wattage
208V
3,000
20
4,000
25
4,500
30
5,000
30
5,500
35
6,000
40
8,000
50
9,000
-
10,000
-
11,000
-
12,000
-
Installation Checklist
Tank location:
1.
Does room size require a louvered door, ducting kit, or similar ventilation? 10 ft x 10 ft x 7 ft or
700 ft
3
(19.8 m
7 in (17.5 cm) clearance at the rear of the unit and at least 7 in (17.5 cm) clearance around the
sides of the unit. 6 in (15.2 cm) clearance for earthquake strap installations, with additional
clearance on the opposite side of the unit).
Front of unit is free and clear.
Is the water heater level? If no, add shims under the base of the unit to ensure proper function of
sensors.
2.
Verify Air Filter is installed (located in packaging).
3.
Plumbing connections:
Ensure that air filter removal is not prevented.
Check for leaks after filling the tank with water, when water is or isn't flowing.
Condensate lines are in place:
4.
Main flexible or rigid drain line must be installed and directed to a drain or condensate pump.
Reducer fittings are not recommended.
Temperature and pressure-relief valve is working and drain line completed per local code.
5.
6.
Electrical:
Verify 208/240 VAC to L1 and L2 at tank.
Ensure that the electrical connection does not prevent air filter removal.
7.
Verify that the control panel displays 120ºF (49ºC) in Hybrid Mode. Assist user in how to adjust
temperature and modes (see "Water Temperature Adjustment" section).
Recommended Over-Current
amperage rating)
240V
277V
20
15
25
20
25
25
30
25
30
25
35
30
45
40
50
45
-
50
-
50
-
-
3
), or 240 in
2
(0.15 m²) open air-flow area needed.
Total Water
Heater Wattage
480V
3,000
15
4,000
15
15
4,500
5,000
15
5,500
15
6,000
20
8,000
25
9,000
25
10,000
30
11,000
30
12,000
35
Copper Wire Size AWG Based on
N.E.C. Table 310-16 (167ºF/75ºC.)
208V
240V
277V
12
12
14
10
10
12
10
10
10
10
10
10
8
10
10
8
8
10
8
8
8
-
8
8
-
-
8
-
-
8
-
-
-
480V
14
14
14
14
14
12
10
10
10
10
8
19

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Re2h65t 1nctt seriesRe2h80t 1nctt series

Table of Contents