Bradford White Heat Pump Water Heater RE2H50, RE2H80
IMPORTANT SAFETY NOTICE
This information is intended for use by individuals
possessing adequate background of electrical, electronic
and mechanical experience. Any attempt to repair
a major appliance may result in personal injury and
property damage. The manufacturer or seller cannot be
responsible for the interpretation of this information, nor
can it assume any liability in connection with its use. This
quick reference guide is provided for information purposes
only and does not replace, modify or change in any
manner the Owner's Manual and Installation Instructions.
DISCONNECT POWER BEFORE SERVICING
IMPORTANT- RECONNECT ALL GROUNDING DEVICES
All parts of this appliance capable of conducting electrical
current are grounded. If grounding wires, screws, straps,
clips, nuts or washers used to complete a path to ground
are removed for service, they must be returned to their
original condition and properly fastened.
Display
Displays the current
temperature or the number
of days for vacation mode.
To display setpoint if display
has gone blank, press any
button.
Heat Pump
(Only)
Utilizes heat pump only.
Hybrid
Utilizes the heat pump and
electric heating elements.
Electric
(Only)
Utilizes electric elements
only. Stops the fan, the
heat pump and the flow of
cool air.
Vacation
Use this mode for periods
away from home.
Mode
Press this button to toggle
through the various heating
modes. Press and hold to
switch between ºF and ºC.
CAUTION
Double wall heat exchanger, suitable for potable water
connection.
SPECIFICATIONS
Capacity ..................................................................... 50/80 US gal
Tank Max Working Pressure ........................................ 150 PSI
Water Temperature Set Point Range .......... 100F - 140F
Electrical ............................................ 240/208VAC 60 Hz 1-PH
Circuit Breaker ................................................................... 30 Amp
Upper Element Wattage .........................................4500/3380
Lower Element Wattage .........................................4000/3004
REFRIGERATION SYSTEM
Compressor ............................................................................ 500 W
Refrigerant Charge (R134a) ..29.1/30.9 oz (50Gal/80Gal)
Compressor LRA ..................................................................14.0A
Compressor RLA ..................................................................2.56A
Typical High Side Pressure (70°F amb) ..... 210-280 PSIA
Typical Low Side Pressure (70°F amb) ............55-65 PSIA
Arrow Pad
Use the up and down
arrows to manually change
the water temperature, or to
select days for Vacation Mode.
Enter
Press to confirm selections.
Filter
The red LED indicates that
the filter needs cleaning.
Press and hold to reset.

Advertisement

loading

Summary of Contents for Bradford White RE2H50

  • Page 1 Bradford White Heat Pump Water Heater RE2H50, RE2H80 CAUTION IMPORTANT SAFETY NOTICE Double wall heat exchanger, suitable for potable water This information is intended for use by individuals connection. possessing adequate background of electrical, electronic and mechanical experience. Any attempt to repair...
  • Page 2: Service Mode

    T5 Ambient Air SERVICE MODE Sensor The Service Mode can be accessed by pressing and holding the UP Arrow and Enter buttons simultaneously for 5 seconds. You will first hear a T4 Compressor Outlet Sensor single beep when pressing the buttons, then a two-tone sound indicating the action was successful.
  • Page 3 Fault Fault Counts Condition Check Code Before Code Displayed Displayed Control checks to ensure evaporator is free of frost. Continuously verifies Check T3a sensor mounting, wiring and resistance. that T3a sensor (evaporator inlet temperature) is greater than 20F after Check Electronic Expansion Valve (EEV) operation. 30 minutes of run time.
  • Page 4: Electronic Expansion Valve (Eev)

    Electronic Expansion Valve (EEV) This valve replaces the capillary tube typically used in refrigeration appliances. The EEV meters the flow of liquid refrigerant entering the evaporator at the rate that matches the amount of refrigerant being boiled off in the evaporator (gas).
  • Page 5 TOP COVER SHROUD AREA GRAY BLACK Sheet Metal Control Board RJ-45 J501 (Tank) T2 J701 J801 YELLOW CT201 (Evaporator Inlet) T3a (Evaporator Outlet) T3b Level J702 K305 / 6 K302 K304 K301 K303 Sensor J502 (Compressor Discharge) T4 COMP Condensate Pan (Ambient) T5 J703 J301...