About The System; Components In A Typical System Layout; Quick Guide; User Permission Level - Daikin Altherma 3 M EDLA09-16D3V3 Operation Manual

Table of Contents

Advertisement

3 About the system

(example: open flames, an operating
gas appliance or an operating electric
heater).
WARNING
▪ Do NOT pierce or burn refrigerant
cycle parts.
▪ Do NOT use cleaning materials or
means to accelerate the defrosting
process other than those
recommended by the manufacturer.
▪ Be aware that the refrigerant inside
the system is odourless.
WARNING
The refrigerant inside the unit is mildly
flammable, but normally does NOT
leak. If the refrigerant leaks in the room
and comes in contact with fire from a
burner, a heater, or a cooker, this may
result in fire, or the formation of a
harmful gas.
Turn off any combustible heating
devices, ventilate the room, and
contact the dealer where you
purchased the unit.
Do NOT use the unit until a service
person confirms that the part from
which the refrigerant leaked has been
repaired.
WARNING
Air purging heat emitters or
collectors. Before you purge air from
heat emitters or collectors, check if
or
is displayed on the home screen
of the user interface.
▪ If not, you can purge air immediately.
▪ If yes, make sure that the room
where you want to purge air is
sufficiently ventilated. Reason:
Refrigerant might leak into the water
circuit, and subsequently into the
room when you purge air from the
heat emitters or collectors.
3
About the system
Depending on the system layout, the system can:
▪ Heat up a space
Operation manual
4
▪ Cool down a space
▪ Produce domestic hot water (if a DHW tank is installed)
INFORMATION
Cooling is only applicable in case of reversible models.
INFORMATION
If underfloor heating is installed in the main zone, then in
cooling mode the main zone can only provide refreshment.
Real cooling is then NOT allowed.
3.1
Components in a typical system
layout
C
d
f
a
A
Main zone. Example: Living room.
B
Additional zone. Example: Bedroom.
C
Technical room. Example: Garage.
a
Outdoor unit heat pump
b
Underfloor heating
c
Heat pump convectors or fan coil units
d
User interface
e
Dedicated Human Comfort Interface (BRC1HHDA used as
room thermostat)
f
Domestic hot water (DHW) tank
4

Quick guide

4.1

User permission level

The amount of information you can read out and edit in the menu
structure depends on your user permission level:
▪ User: Standard mode
▪ Advanced user: You can read out and edit more information
To change the user permission level
1 Go to [B]: User profile.
B
User profile
2 Enter the applicable pin code for the user permission
level.
▪ Browse through the list of digits and change the
selected digit.
▪ Move the cursor from left to right.
▪ Confirm the pin code and proceed.
User pin code
The User pin code is 0000.
B
A
c
e
b
EBLA09~16DA + EDLA09~16DA
Daikin Altherma 3 M
4P620243-1B – 2021.02